Simple ultraviolet calibration source with reference spectra and its use with the Galileo orbiter ultraviolet spectrometer
- 1 March 1988
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 27 (5) , 890-914
- https://doi.org/10.1364/ao.27.000890
Abstract
We have developed a simple compact electron impact laboratory source of UV radiation whose relative intensity as a function of wavelength has an accuracy traceable to the fundamental physical constants (transitions probabilities and excitation cross sections) for an atomic or molecular system. Using this laboratory source, calibrated optically thin vacuum ultraviolet (VUV) spectra have been obtained and synthetic spectral models developed for important molecular band systems of H2 and N2 and the n1P0 Rydberg series of He. The model spectrum from H2 represents an extension of the molecular branching ratio technique to include spectral line intensities from more than one electronic upper state. The accuracy of the model fit to the VUV spectra of H2 and N2 is sufficient to predict the relative spectral intensity of the electron impact source and to serve as a primary calibration standard for VUV instrumentation in the 80–230-nm wavelength range. The model is applicable to VUV instrumentation with full width at half-maximum ≥0.4 nm. The present accuracy is 10% in the far ultraviolet (120–230 nm), 10% in the extreme ultraviolet (EUV) (90–120 nm), and 20% in the EUV (80–90 nm). The n1P0 Rydberg series of He has been modeled to 10% accuracy and can be considered a primary calibration standard in the EUV (52.2–58.4 nm). A calibrated optically thin spectrum of Ar has been obtained at 0.5-nm resolution and 200-eV electron impact energy to 35% accuracy without benefit of models over the EUV spectral range of 50–95 nm. The Ar spectrum expands the ultimate range of the VUV relative calibration using this source with the four gases, He, Ar, H2, and N2, to 50–230 nm. The calibration of the Galileo orbiter ultraviolet spectrometer for the upcoming Jupiter mission has been demonstrated and compared to results from other methods.Keywords
This publication has 28 references indexed in Scilit:
- Transition probabilities for the D and B′ vibrational levels to the X vibrational levels and continuum of H2Atomic Data and Nuclear Data Tables, 1984
- Studies of extreme-ultraviolet emission from Rydberg series ofby electron impactPhysical Review A, 1984
- Electron–photon coincidence technique for the absolute calibration of VUV detectorsApplied Optics, 1983
- Deuterium lamp based monochromator calibration extended down to 115 nmApplied Optics, 1981
- VUV radiometry below 100 nm: the high-power hydrogen arc as a standard source of continuum radiation between 53 nm and 92 nmApplied Optics, 1979
- Polarisation of the 104.8 and 106.7 nm Ar resonance lines following electron impact excitationJournal of Physics B: Atomic and Molecular Physics, 1977
- Vacuum ultraviolet radiation scales: an accurate comparison between plasma blackbody lines and synchrotron radiationApplied Optics, 1977
- Angular distributions and polarization fractions of helium resonance radiation (nP1−1S1) in the extreme ultravioletPhysical Review A, 1974
- Intensity Calibration using Molecular Bands Excited by Controlled Electron ImpactJournal of the Optical Society of America, 1969