Femoral component migration in total knee arthroplasty: Randomized study comparing cemented and uncemented fixation of the Miller‐Galante I design
- 1 May 1995
- journal article
- clinical trial
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 13 (3) , 347-356
- https://doi.org/10.1002/jor.1100130308
Abstract
The Miller‐Galante I knee replacement was inserted in 25 women and three men (33 knees) with osteoarthrosis. All patients received a TiAIV femoral component with a commercially pure titanium fibermesh undersurface. Cemented or cementless fixation was used based on a randomization protocol. Micromotions of the femoral components were recorded with roentgen stereophotogrammetric analysis during the first 2 postoperative years. The magnitude of migration did not differ between cemented and uncemented fixation. The number of nonmigrating prostheses decreased from 21 (12 cemented and nine uncemented) at 3 months to six (three cemented and three uncemented) at 24 months. In both groups, the magnitude of prosthetic tilting about the longitudinal axis (internal‐external rotation) was as large as that about the transverse axis (flexion‐extension). Rotation into extension was as common as rotation into flexion. The largest translations were recorded at either of the posterior condyles. In 10 uncemented components, radiolucent lines were seen at the distal interface postoperatively. Proximal migration of the femoral component was recorded in these knees, and the width of the lines decreased or the lines disappeared totally at 24 months. After 2 years, lines were noted around four cemented and four uncemented replacements, mainly anteriorly or distally. All of these prostheses migrated. One prosthesis, revised because of malalignment, displayed pronounced migration after an initial period of stability. Bone ingrowth was observed anteriorly and anterodistally despite the presence of motions of 1 mm or more.Keywords
This publication has 31 references indexed in Scilit:
- Three‐dimensional knee joint movements during a step‐up: Evaluation after anterior cruciate ligament ruptureJournal of Orthopaedic Research, 1994
- Migration of porous coated acetabular prostheses fixed with screws: Roentgen stereophotogrammetric analysisJournal of Orthopaedic Research, 1992
- Porous-Coated Anatomic Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1991
- Two-to Four-Year Results of Posterior Cruciate-Sparing Condylar Total Knee Arthroplasty With an Uncemented Femoral ComponentPublished by Wolters Kluwer Health ,1990
- Cemented and Ingrowth Fixation of the Miller???Galante ProsthesisClinical Orthopaedics and Related Research, 1990
- Mechanisms of Failure of the Femoral and Tibial Components in Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1989
- The Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring SystemClinical Orthopaedics and Related Research, 1989
- Patellar Component Failure in Cementless Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1988
- Noncemented Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1986
- Technical Accuracy in High Tibial Osteotomy for GonarthrosisActa Orthopaedica, 1980