In-house nucleic acid amplification tests for the detection of Mycobacterium tuberculosis in sputum specimens: meta-analysis and meta-regression
Open Access
- 3 October 2005
- journal article
- research article
- Published by Springer Nature in BMC Microbiology
- Vol. 5 (1) , 55
- https://doi.org/10.1186/1471-2180-5-55
Abstract
Background: More than 200 studies related to nucleic acid amplification (NAA) tests to detect Mycobacterium tuberculosis directly from clinical specimens have appeared in the world literature since this technology was first introduced. NAA tests come as either commercial kits or as tests designed by the reporting investigators themselves (in-house tests). In-house tests vary widely in their accuracy, and factors that contribute to heterogeneity in test accuracy are not well characterized. Here, we used meta-analytical methods, including meta-regression, to identify factors related to study design and assay protocols that affect test accuracy in order to identify those factors associated with high estimates of accuracy. Results: By searching multiple databases and sources, we identified 2520 potentially relevant citations, and analyzed 84 separate studies from 65 publications that dealt with in-house NAA tests to detect M. tuberculosis in sputum samples. Sources of heterogeneity in test accuracy estimates were determined by subgroup and meta-regression analyses. Among 84 studies analyzed, the sensitivity and specificity estimates varied widely; sensitivity varied from 9.4% to 100%, and specificity estimates ranged from 5.6% to 100%. In the meta-regression analysis, the use of IS6110 as a target, and the use of nested PCR methods appeared to be significantly associated with higher diagnostic accuracy. Conclusion: Estimates of accuracy of in-house NAA tests for tuberculosis are highly heterogeneous. The use of IS6110 as an amplification target, and the use of nested PCR methods appeared to be associated with higher diagnostic accuracy. However, the substantial heterogeneity in both sensitivity and specificity of the in-house NAA tests rendered clinically useful estimates of test accuracy difficult. Future development of NAA-based tests to detect M. tuberculosis from sputum specimens should take into consideration these findings in improving accuracy of in-house NAA tests.Keywords
This publication has 51 references indexed in Scilit:
- Systematic reviews of diagnostic test evaluations: what's behind the scenes?BMJ Evidence-Based Medicine, 2004
- Detección de Mycobacterium tuberculosis mediante la reacción en cadena de la polimerasa en una población seleccionada del noroccidente de MéxicoRevista Panamericana de Salud Pública, 2000
- Improvement of Mycobacterium tuberculosis detection in clinical samples using DNA purified by glass matrixJournal of Microbiological Methods, 1997
- Clinical Evaluation of Polymerase Chain Reaction DNA Amplification Method for the Diagnosis of Pulmonary Tuberculosis in Patients with Negative Acid-fast Bacilli Smear.The Tohoku Journal of Experimental Medicine, 1995
- Rapid Detection of Mycobacterial DNA in Clinical Samples by Multiplex PCRDiagnostic Molecular Pathology, 1994
- The diagnostic use of the polymerase chain reaction for the detection of Mycobacterium tuberculosisPathology, 1994
- Polymerase chain reaction for detection ofMycobacterium tuberculosis in sputumEuropean Journal of Clinical Microbiology & Infectious Diseases, 1993
- Use of PCR in routine diagnosis of treated and untreated pulmonary tuberculosis.Journal of Clinical Pathology, 1993
- Evaluation of Polymerase Chain Reaction, Tuberculostearic Acid Analysis, and Direct Microscopy for the Detection of Mycobacterium tuberculosis in SputumThe Journal of Infectious Diseases, 1992
- Evaluation of a polymerase chain reaction for the diagnosis of tuberculosisTubercle, 1991