Comparison of the fixation of subcapital femoral neck osteotomies with absorbable self-reinfoced poly-L-lactide lag-screws or metallic screws in sheep
- 1 January 1997
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 15 (1) , 124-127
- https://doi.org/10.1002/jor.1100150118
Abstract
Seven subcapital femoral osteotomies of adult sheep were each fixed with two absorbable self-reinforced poly-L-lactide lag-screws, and seven other osteotomies were each fixed with two metallic cancellous bone screws. At 3 and 12 weeks, radiographs were taken and callus formation, displacement, and union were evaluated. At 12 weeks, the animals were killed and strength measurements were carried out. According to the radiographs, union was achieved in six of seven osteotomies in both groups, while after 3 weeks one fixation in both the group treated with absorbable screws and the group treated with metallic screws had failed. There were no statistical differences between the groups with respect to callus formation or displacement. Regarding the strength of the osteotomized bones, at 12 weeks there were no statistically significant differences in the load-carrying capacity between the bones fixed with self-reinforced poly-L-lactide screws and those fixed with metallic screws. These results showed that self-reinforced poly-L-lactide screws, which have been used successfully in fractures and osteotomies in cancellous bone, are strong enough to support this more demanding fixation of weight-bearing bones.Keywords
This publication has 7 references indexed in Scilit:
- Fixation of subcapital femoral osteotomies by poly-L-lactic acid pinsInternational Orthopaedics, 1993
- Shear strength of cancellous bone after osteotomy fixed with absorbable self-reinforced polyglycolic acid and poly-L-lactic acid rodsJournal of Materials Science: Materials in Medicine, 1992
- Absorbable self-reinforced polylactide (SR-PLA) composite rods for fracture fixation: strength and strength retention in the bone and subcutaneous tissue of rabbitsJournal of Materials Science: Materials in Medicine, 1992
- Polylactide screws in the fixation of olecranon osteotomies A mechanical study in sheepActa Orthopaedica, 1992
- Bone weakness after the removal of plates and screws. Cortical atrophy or screw holes?The Journal of Bone and Joint Surgery. British volume, 1991
- BIODEGRADABLE IMPLANTS IN FRACTURE FIXATION: EARLY RESULTS OF TREATMENT OF FRACTURES OF THE ANKLEThe Lancet, 1985
- The direct lateral approach to the hipThe Journal of Bone and Joint Surgery. British volume, 1982