Fermentation monitoring using a glucose biosensor based on an electrocatalytically bulk-modified epoxy–graphite biocomposite integrated in a flow system
- 1 January 1995
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 120 (8) , 2255-2258
- https://doi.org/10.1039/an9952002255
Abstract
Glucose oxidase (GOD) and metals for the electrocatalytic oxidation of hydrogen peroxide were incorporated in the bulk of a graphite–epoxy composite. An amperometric glucose biosensor based on this biocomposite material made of graphite–epoxy–Au–Pd–GOD was integrated in a flow injection system and used for discrete glucose monitoring of a bioprocess. Stability, reproducibility and flow parameters related to the flow injection system were studied. The analytical system showed a linear response for glucose in the range 10–5–10–2 mol l–1 when a potential of 900 mV was applied with respect to an Ag/AgCl electrode. A solution of 0.1 mol l–1 phosphate and 0.1 mol l–1 KCl buffered to pH 7 was used as the carrier solution. The reproducibility of the signal was below 5% and the sampling frequency was about 20 samples h–1. For the final application, the linear working response range was adapted from 1 to 10 g l–1 of glucose. The results obtained were compared with those obtained with a commercially available glucose sensor and by HPLC.Keywords
This publication has 9 references indexed in Scilit:
- Amperometric glucose biosensor based on a tetrathiafulvalene‐mediated epoxy‐graphite biocompositeElectroanalysis, 1994
- Amperometric determination of pesticides using a biosensor based on a polishable graphie-epoxy biocompositeAnalytica Chimica Acta, 1994
- Amperometric glucose biosensor based on an electrocatalytically bulk-modified epoxy-graphite biocompositeAnalytica Chimica Acta, 1993
- Amperometric enzymatic glucose electrode based on an epoxy-graphite compositeAnalytica Chimica Acta, 1993
- Bulk modified enzyme electrodes for reagentless detection of peroxidesBioelectrochemistry and Bioenergetics, 1991
- A polishable amperometric biosensor for bilirubinElectroanalysis, 1990
- Polishable and robust biological electrode surfacesAnalytical Chemistry, 1990
- A glucose sensor made by chemically crosslinking glucose oxidase directly on the surface of a carbon electrode modified with Pd/Au for hydrogen peroxide electrocatalysisMicrochimica Acta, 1989
- A comparison of glassy-carbon and carbon—polymer composite electrodes incorporated into electrochemical detection systems for high-performance liquid chromatographyTalanta, 1988