On counting and counting errors
Top Cited Papers
- 8 April 2002
- journal article
- review article
- Published by Wiley in Journal of Comparative Neurology
- Vol. 447 (1) , 1-7
- https://doi.org/10.1002/cne.10221
Abstract
Counting objects in histological sections is often a necessary, sometimes an unexpected part of a research project. The recent literature shows that the subject of counting is of particular interest to readers of the Journal of Comparative Neurology but that it is also contentious and difficult. Even a brief review of past issues of the Journal shows that there are many misconceptions about counting and that there remain issues that have received little or no attention. Counts are subject to many errors. Some reports include readily recognizable errors, others fail to include all of the information that is needed for an evaluation of their accuracy. This review is above all a plea for adequate information about the methods used for counts in all publications. It serves to help those who are new to quantitative methods in histology; it considers some of the basic issues arising for anyone undertaking counts, or reviewing manuscripts that include counts. In particular, it considers recently introduced or re‐introduced counting methods that depend on accurate measures along the axis perpendicular to the plane of the sections, and looks at the difficulties inherent in these measures. J. Comp. Neurol. 447:1–7, 2002.Keywords
This publication has 22 references indexed in Scilit:
- Benes and Lange respond: reconciling theory and practice in cell countingTrends in Neurosciences, 2001
- The efficiency of systematic sampling in stereology — reconsideredJournal of Microscopy, 1999
- Methods for determining numbers of cells and synapses: A case for more uniform standards of reviewJournal of Comparative Neurology, 1996
- Estimate of the total number of neurons and glial and endothelial cells in the rat spinal cord by means of the optical disectorJournal of Comparative Neurology, 1993
- Three‐dimensional counting: An accurate and direct method to estimate numbers of cells in sectioned materialJournal of Comparative Neurology, 1988
- The new stereological tools: Disector, fractionator, nucleator and point sampled intercepts and their use in pathological research and diagnosisAPMIS, 1988
- The unbiased estimation of number and sizes of arbitrary particles using the disectorJournal of Microscopy, 1984
- Determining Sizes and Distribution of Sizes of Spherical Bodies such as Chromaffin Granules in Tissue SectionsNature, 1968
- Estimation of nuclear population from microtome sectionsThe Anatomical Record, 1946
- Paraffin Section Thickness—A Direct Method of MeasurementStain Technology, 1944