Integration of digital fluoroscopy with CT‐based radiation therapy planning of lung tumors
- 16 July 2002
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 29 (8) , 1698-1709
- https://doi.org/10.1118/1.1495864
Abstract
Radiation dose escalation may be a means to increase the local control rate of inoperable lung tumors. Treatment plans involve the creation of a uniform planning target volume (PTV) to ensure proper coverage despite patient breathing and setup error. This may lead to unnecessary radiation of normal tissue in shallow breathers or target underdosing for patients with excess internal motion. Therefore, the nature of tumor motion for each patient should be measured in 3D, something that cannot be done with CT alone. We have developed a method that acquires 2D real‐time fluoroscopic images (loops) and coregisters them with 2D digitally reconstructed radiographs (DRR) formed from the CT scan. The limitations of CT to encompass motion can be overcome by merging the two modalities together. The accuracy of the coregistration method is tested with a stationary grid of radio‐opaque markers at various spatial positions. The in‐plane (at‐depth) displacement between markers on the fluoroscopic image versus the DRR varies with position across the image due to slight misalignments between the x‐ray source used in fluoroscopy and the virtual source used for the DRR relative to the test object. At clinically relevant positions, the maximum, measured in‐plane displacement, is 1.1 mm. The method is applied to the thorax of an anthropomorphic phantom and a good fit is observed between the appearances of the bony anatomical structures on the coregistered image. Finally, a series of motion measurements are carried out on two oscillating cylindrical objects. The degree of motion as measured by fluoroscopy is accurate to within 1.0 mm, whereas the DRR is inconsistent in predicting motion. The coregistration of fluoroscopic loops with the DRR shows at what point within the oscillation the DRR fails to encompass motion. For any treatment site involving target motion, this real‐time imaging is a useful asset in the planning stage.Keywords
This publication has 24 references indexed in Scilit:
- Integration of digital fluoroscopy with CT simulation: patient specific planning target volumesInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Multiple “slow” CT scans for incorporating lung tumor mobility in radiotheraphy planningInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patientsMedical Physics, 2001
- A new approach to dose escalation in non–small-cell lung cancerInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Lung cancer: Combined modality therapy in NSCLCAnnals of Oncology, 2000
- Continuous, hyperfractionated, accelerated radiotherapy (CHART) versus conventional radiotherapy in non-small cell lung cancer: mature data from the randomised multicentre trialRadiotherapy and Oncology, 1999
- Dose escalation for non-small cell lung cancer using conformal radiation therapyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- 3D conformal radiotherapy in the sagittal plane for centrally located thoracic tumorsMedical Dosimetry, 1995
- Three-dimensional conformal radiotherapy in bronchogenic carcinoma: considerations for implementationLung Cancer, 1994
- Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomographyInternational Journal of Radiation Oncology*Biology*Physics, 1990