Artificial colloids impair haemostasis. An in vitro study using thromboelastometry coagulation analysis
- 8 February 2005
- journal article
- clinical trial
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 49 (3) , 373-378
- https://doi.org/10.1111/j.1399-6576.2005.00619.x
Abstract
Hydroxyethyl starch (HES) solutions impair haemostatic mechanisms. The impact of the degree of substitution (DS) of a HES solution on thromboelastometry tracings is unclear. Therefore we tested the hypothesis of whether the DS has an effect on the haemostatic defect caused by HES, and assessed whole blood coagulation by thromboelastometry coagulation analysis (ROTEM, Pentapharm Co., Munich, Germany) in serial in vitro haemodilutions of colloids. Whole blood was withdrawn from 12 volunteers in a crossover study. Six per cent low-molecular weight HES with a high (HES MW 120 kDa/degree of substitution 0.7) and low (HES MW 130 kDa/0.4) degree of substitution, 4% succinylated gelatin (GEL) or 4% albumin (ALB) was added to citrated venous whole blood samples to make 20, 40, 60 vol.% end-concentrations of each of the solutions. Samples were analyzed by ROTEM. There was a comparable decrease in maximum clot firmness (MCF) and shear elastic modulus [G = 5000 x MCF/(100-MCF)] by HES 120/0.7 and HES 130/0.4 at 20 and 40 vol.% dilutions. At 60 vol.% dilution HES 120/0.7 decreased less alpha-angle and MCF than HES 130/0.4 (P < 0.05). With moderate dilutions all colloids shortened coagulation time (CT). At 20, 40 and 60 vol.% dilutions MCF and G were more decreased in both HES groups than in the ALB and GEL groups (P < 0.05). Furthermore, at 40 and 60 vol.% dilutions G deteriorated more in the GEL than in the ALB group (P < 0.05). In vitro the impact of the degree of substitution of HES solution on thromboelastometry coagulation analysis was modest. Haemodilution with gelatin and albumin induced fewer coagulation abnormalities than HES. In addition, the haemodilution with gelatin impaired coagulation more than albumin solution.Keywords
This publication has 29 references indexed in Scilit:
- Hydroxyethyl Starch as a Priming Solution for Cardiopulmonary Bypass Impairs Hemostasis After Cardiac SurgeryAnesthesia & Analgesia, 2004
- The effects of hydroxyethyl starch solutions on thromboelastography in preoperative male patientsActa Anaesthesiologica Scandinavica, 2002
- The Effect of the Combined Administration of Colloids and Lactated Ringer’s Solution on the Coagulation System: An In Vitro Study Using Thrombelastograph® Coagulation Analysis (ROTEG®)Anesthesia & Analgesia, 2002
- The Effects of Hydroxyethyl Starches of Varying Molecular Weights on Platelet FunctionAnesthesia & Analgesia, 2001
- Citrate Storage Affects Thrombelastograph®AnalysisAnesthesiology, 2000
- In Vitro Effects of Different Medium Molecular Hydroxyethyl Starch Solutions and Lactated Ringer’s Solution on Coagulation Using SONOCLOTAnesthesia & Analgesia, 2000
- Hydroxyethyl starch impairsin vitrocoagulationActa Anaesthesiologica Scandinavica, 1998
- Use of modified fluid gelatin and hydroxyethyl starch for colloidal volume replacement in major orthopaedic surgeryBritish Journal of Anaesthesia, 1997
- HES 200/0.5 Is not HES 200/0.5Thrombosis and Haemostasis, 1995
- Influence of Different Intravascular Volume Therapies on Platelet Function in Patients Undergoing Cardiopulmonary BypassAnesthesia & Analgesia, 1993