Performance of the ARX-derived Auditory Evoked Potential Index as an Indicator of Anesthetic Depth
Top Cited Papers
- 1 April 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (4) , 803-816
- https://doi.org/10.1097/00000542-200204000-00006
Abstract
Background: Autoregressive modeling with exogenous input of middle-latency auditory evoked potential (A-Line autoregressive index [AAI]) has been proposed for monitoring anesthetic depth. The aim of the current study was to compare the accuracy of this new index with the Bispectral Index (BIS), predicted effect-site concentration of propofol, and hemodynamic measures. Methods: Twenty female patients scheduled for ambulatory gynecologic surgery received effect compartment controlled infusion of propofol. Target effect-site concentration was started at 1.5 microg/ml and increased every 4 min by 0.5 microg/ml. At every step, sedation level was compared with monitoring values using different clinical scoring systems and reaction to noxious stimulus. Results: Bispectral Index, AAI, and predicted propofol effect-site concentration were accurate indicators for the level of sedation and loss of consciousness. Hemodynamic variables were poor indicators of the hypnotic-anesthetic status of the patient. BIS correlated best with propofol effect-site concentration, followed by AAI. Hemodynamic measurements did not correlate well. No indicators predicted reaction to noxious stimulus. Poststimulus, BIS and AAI showed an increase as a result of arousal. This reaction occurred more rapidly with the AAI than with BIS. Conclusion: Bispectral Index, AAI, and predicted propofol effect-site concentration revealed information on the level of sedation and loss of consciousness but did not predict response to noxious stimulus.Keywords
This publication has 32 references indexed in Scilit:
- Changes in rapidly extracted auditory evoked potentials during tracheal intubationActa Anaesthesiologica Scandinavica, 2000
- Changes in the Auditory Evoked Potentials and the Bispectral Index following Propofol or Propofol and AlfentanilAnesthesiology, 2000
- Approximate Entropy as an Electroencephalographic Measure of Anesthetic Drug Effect during Desflurane AnesthesiaAnesthesiology, 2000
- Forty-hertz Midlatency Auditory Evoked Potential Activity Predicts Wakeful Response during Desflurane and Propofol Anesthesia in VolunteersAnesthesiology, 1999
- Comparison of bispectral index, 95% spectral edge frequency and approximate entropy of the EEG, with changes in heart rate variability during induction of general anaesthesiaBritish Journal of Anaesthesia, 1999
- On-line analysis of middle latency auditory evoked potentials (MLAEP) for monitoring depth of anaesthesia in laboratory ratsMedical Engineering & Physics, 1999
- Auditory evoked potential index: a quantitative measure of changes in auditory evoked potentials during general anaesthesiaAnaesthesia, 1997
- Assessment of anaesthesia depthActa Anaesthesiologica Scandinavica, 1996
- Classification of single-trial ERP sub-types: application of globally optimal vector quantization using simulated annealingElectroencephalography and Clinical Neurophysiology, 1995
- Single evoked potential reconstruction by means of wavelet transformBiological Cybernetics, 1992