Measurement of Absolute Wavelength Stability of Lasers
- 1 February 1966
- journal article
- Published by Optica Publishing Group in Journal of the Optical Society of America
- Vol. 56 (2) , 156-161
- https://doi.org/10.1364/josa.56.000156
Abstract
A technique was devised to measure the absolute wavelength stability of a gas laser by direct interferometric comparison with a mercury 198 standard lamp. The apparatus used is described; its limits of precision are discussed.The wavelength fluctuations of a free-running, unstabilized helium-neon laser were measured and found to be several parts in 107. They are attributed to thermal and mechanical instabilities of the laser cavity.Manual control of the laser was seen to yield a wavelength constancy of a few parts in 108, comparable to the limits of accuracy of interferometric standard sources.Keywords
This publication has 6 references indexed in Scilit:
- Gas Mixtures and Pressures for Optimum Output Power of rf-Excited Helium–Neon Gas Lasers at 6328 nmApplied Optics, 1965
- Frequency Stability of He-Ne Masers and Measurements of LengthPhysical Review Letters, 1963
- Frequency Characteristics of a Continuous-Wave He–Ne Optical MaserJournal of the Optical Society of America, 1962
- Gaseous Optical MasersApplied Optics, 1962
- Infrared and Optical MasersPhysical Review B, 1958
- The Luminosity of Spectrometers with Prisms, Gratings, or Fabry-Perot EtalonsJournal of the Optical Society of America, 1954