Parametric back-action effects in a high-Q cyrogenic sapphire transducer
- 1 July 1996
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 67 (7) , 2435-2442
- https://doi.org/10.1063/1.1147193
Abstract
The construction and operation of a high‐quality factor microwavesapphireresonatortransducer coupled to a 1 kHz niobium membrane acoustic oscillator are presented in this paper. A four‐stage passive vibration isolation system was included in the design to permit the measurement of the transducer’s parametric properties. The isolation system was shown to sufficiently suppress mechanical noise above 100 Hz and an upper limit to the displacement sensitivity of the transducer was measured to be 3.0±0.6×10−16 m/√Hz. The parametric behavior of the transducer with a single pump readout was measured for several transducer configurations, and the results were found to be in good agreement with theory. The measurements presented here display for the first time the complete parametric behavior in a high electrical Q system, where the transducer’s bandwidth is less than the mechanical oscillator’s frequency. The high stability and low losses of our system may allow the transducer to be configured as a back‐action evasion or quantum nondemolition device.Keywords
This publication has 22 references indexed in Scilit:
- Sensitivity analysis of a resonant-mass gravitational wave antenna with a parametric transducerReview of Scientific Instruments, 1995
- High Sensitivity Gravitational Wave Antenna with Parametric Transducer ReadoutPhysical Review Letters, 1995
- Back-action-evading transducing scheme for cryogenic gravitational wave antennasPhysical Review D, 1993
- Long-term operation of the Rome "Explorer" cryogenic gravitational wave detectorPhysical Review D, 1993
- A cryogenic double-resonant parabridge motion transducer for resonant-mass gravitational wave detectorsReview of Scientific Instruments, 1991
- Numerical analysis of the performance of a resonant gravity-wave detectorPhysical Review D, 1989
- Parametric Transducer for Gravitational Radiation DetectorJapanese Journal of Applied Physics, 1986
- Experimental verification of a single transducer back-action evading measurement scheme for a gravitational wave detectorPhysics Letters A, 1984
- Design and preparation of high-Q niobium reentrant cavities for physics measurementsReview of Scientific Instruments, 1983
- Gravitational Shielding and AbsorptionPhysical Review B, 1966