A comparative study of the efficacy of beclomethasone dipropionate delivered from a breath activated and conventional metered dose inhaler in asthmatic patients
- 1 January 1993
- journal article
- clinical trial
- Published by Taylor & Francis in Current Medical Research and Opinion
- Vol. 13 (2) , 61-69
- https://doi.org/10.1185/03007999309111534
Abstract
In order to overcome the problem of poor co-ordination with the use of the conventional press and breathe metered dose inhaler, a breath-activated inhaler ('Autohaler' inhalation device) has been developed. The clinical response to equal doses of beclomethasone dipropionate administered from the 'Autohaler' device and the conventional metered dose inhaler was compared in 36 stable asthmatic patients receiving regular inhaled beclomethasone dipropionate. The study was performed using a double-blind, double-dummy crossover design. Each treatment was given for 4 weeks. Objective and subjective measures of asthma severity were compared in the second 14 days of each treatment period, with clinical equivalence defined as a difference of 20% or less in the adjusted mean values for the 30 patients with data from both treatment periods. Equivalence at the +/- 5% level was found in the objective measures of pre-bronchodilator FEV1 (p < or = 0.001); post-bronchodilator FEV1 (p < 0.001); morning and evening peak expiratory flow rate (both p < or = 0.001). Patient diary cards established there was equivalent usage of inhaled bronchodilator, and equivalent symptom scores for daytime disability and daytime and night-time breathlessness. The results show that, in stable asthmatics, treatment with beclomethasone dipropionate is clinically equivalent when delivered by the 'Autohaler' device or the conventional metered dose inhaler used efficiently.Keywords
This publication has 14 references indexed in Scilit:
- Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.Thorax, 1991
- A comparison of the Two One-Sided Tests Procedure and the Power Approach for assessing the equivalence of average bioavailabilityJournal of Pharmacokinetics and Biopharmaceutics, 1987
- Generic Drug Substitution RevisitedNew England Journal of Medicine, 1987
- Errors in Inhalation Technique and Efficiency in Inhaler Use in Asthmatic ChildrenAllergy, 1986
- Beclomethasone dipropionate aerosol compared with dry powder in the treatment of asthmaClinical and Experimental Allergy, 1980
- Beclomethasone dipropionate dry-powder inhalation compared with conventional aerosol in chronic asthma.BMJ, 1978
- A clinical comparison of aerosol and powder administration of beclomethasone dipropionate in asthmaClinical and Experimental Allergy, 1978
- Use of pressurised aerosols by asthmatic patients.BMJ, 1976
- Patient error in use of bronchidilator metered aerosols.BMJ, 1976
- Comparison of Beclomethasone Dipropionate Aerosol and Prednisolone in Reversible Airways ObstructionBMJ, 1972