Identification and Susceptibility Testing of Enterobacteriaceae and Pseudomonas aeruginosa by Direct Inoculation from Positive BACTEC Blood Culture Bottles into Vitek 2
Open Access
- 1 January 2004
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 42 (1) , 7-11
- https://doi.org/10.1128/jcm.42.1.7-11.2004
Abstract
Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the “gold standard.” We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture.Keywords
This publication has 28 references indexed in Scilit:
- Evaluation of the Vitek 2 ID-GNB Assay for Identification of Members of the Family Enterobacteriaceae and Other Nonenteric Gram-Negative Bacilli and Comparison with the Vitek GNI+ CardJournal of Clinical Microbiology, 2003
- Evaluation of the Vitek 2 System for Rapid Identification of Clinical Isolates of Gram-Negative Bacilli and Members of the Family StreptococcaceaeEuropean Journal of Clinical Microbiology & Infectious Diseases, 2002
- Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI+/GNS-GA)Clinical Microbiology & Infection, 2002
- Evaluation of VITEK 2 Rapid Identification and Susceptibility Testing System against Gram-Negative Clinical IsolatesJournal of Clinical Microbiology, 2001
- Potential Impact of the VITEK 2 System and the Advanced Expert System on the Clinical Laboratory of a University-Based HospitalJournal of Clinical Microbiology, 2001
- Evaluation of a new system, VITEK 2, for identification and antimicrobial susceptibility testing of enterococci.2000
- Antimicrobial Susceptibility and Frequency of Occurrence of Clinical Blood Isolates in Europe from the SENTRY Antimicrobial Surveillance Program, 1997 and 1998Clinical Infectious Diseases, 2000
- Bacterial Pathogens Isolated from Patients with Bloodstream Infection: Frequencies of Occurrence and Antimicrobial Susceptibility Patterns from the SENTRY Antimicrobial Surveillance Program (United States and Canada, 1997)Antimicrobial Agents and Chemotherapy, 1998
- Vitek GPS card susceptibility testing accuracy using direct inoculation from Bactec 9240 blood culture bottlesDiagnostic Microbiology and Infectious Disease, 1996
- Automated systems for identification of microorganismsClinical Microbiology Reviews, 1992