Objective. —Transesophageal echocardiography (TEE) and 12-lead electrocardiography (ECG) are sophisticated techniques that are increasingly being used to monitor for myocardial ischemia during noncardiac surgery. We examined whether the routine use of these techniques has incremental clinical value in identifying patients at high risk for perioperative ischemic outcomes when compared with preoperative clinical data and intraoperative monitoring using continuous two-lead bipolar ECG. Design. —Cohort study. Setting. —Veterans Affairs medical center. Patients. —A total of 332 men undergoing noncardiac surgery who had or were at high risk for coronary artery disease. Interventions. —TEE, 12-lead ECG, and two-lead ECG were performed continuously during noncardiac surgery (47% vascular, 53% nonvascular). Monitoring results were not available to anesthesiologists or surgeons, and data were blindly analyzed after surgery. Main Outcome Measure. —Perioperative ischemic outcomes (cardiac death, nonfatal myocardial infarction, unstable angina). Results. —In a subset of 285 patients who were adequately studied by all three techniques, 111 patients (39%) were identified as having intraoperative myocardial ischemia (by one or more monitoring techniques). By univariate analysis, intraoperative ischemia was associated with all perioperative cardiac outcomes, including ischemic outcomes, congestive heart failure, and ventricular tachycardia (P≤.02 for each of the three monitoring techniques). However, when monitoring results for TEE and 12-lead ECG were added to a multivariate model that included preoperative clinical data and continuous two-lead ECG results, the incremental value of TEE was small (odds ratio, 2.6; 95% confidence interval [Cl], 1.2 to 5.7;P=.02) and that of 12-lead ECG was not significant (odds ratio, 1.5; 95% Cl, 0.6 to 3.8). Furthermore, when the multivariate analysis was repeated with only ischemic outcomes, neither TEE nor 12-lead ECG retained significant associations (odds ratio, 2.2; 95% Cl, 0.5 to 9.4, and odds ratio, 1.1; 95% Cl, 0.2 to 6.1, respectively). Conclusion. —When compared with preoperative clinical data and intraoperative monitoring using two-lead ECG, routine monitoring for myocardial ischemia with TEE or 12-lead ECG during noncardiac surgery has little incremental clinical value in identifying patients at high risk for perioperative ischemic outcomes. (JAMA. 1992;268:210-216)Keywords
This publication has 10 references indexed in Scilit:
- Transoesophageal echocardiogram may fail to diagnose peri-operative myocardial infarctionCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1991
- Perioperative Cardiac MorbidityAnesthesiology, 1990
- Inaccuracy of various proposed electrocardiographic criteria in the diagnosis of apical myocardial infarction — a critical reviewEuropean Heart Journal, 1989
- Prospective analysis of electrocardiographic variables as markers for extent and location of acute wall motion abnormalities observed during coronary angioplasty in human subjectsJournal of the American College of Cardiology, 1987
- Determination of Cardiac Risk by Dipyridamole-Thallium Imaging before Peripheral Vascular SurgeryNew England Journal of Medicine, 1985
- Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplastyJournal of the American College of Cardiology, 1985
- Does Perioperative Myocardial Ischemia Lead to Postoperative Myocardial Infarction?Anesthesiology, 1985
- Intraoperative detection of changes in left ventricular segmental wall motion by transesophageal two-dimensional echocardiographyAmerican Heart Journal, 1984
- Myocardial Ischemia during Non-cardiac Surgical Procedures in Patients with Coronary-artery DiseaseAnesthesiology, 1979
- Improved efficiency of treadmill exercise testing using a multiple lead ECG system and basic hemodynamic exercise response.Circulation, 1978