Direct Analysis of Semivolatile Organic Compounds in Air by Atmospheric Pressure Chemical Ionization Mass Spectrometry
- 26 September 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (21) , 5061-5065
- https://doi.org/10.1021/ac010606l
Abstract
Atmospheric pressure chemical ionization is employed for direct air analysis, without ion source modification, by using the sheath gas as the sample transport agent. A simple modification of the sheath gas inlet line allows introduction of gaseous samples into a commercial atmospheric pressure chemical ionization source. Optimization and testing of this novel air sampling method are described and detection of semivolatile compounds is shown. The analytical performance of the technique is established with methyl salicylate, including a limit of quantification of 100 pptr, a limit of detection of 50 pptr, a linear response from 100 pptr to 20 ppb, and rise and fall times of 12 and 20 s, respectively. Using reagent ion monitoring, it is shown that the protonated methanol dimer is the principal CI reagent ion leading to protonated dimethyl methylphosphonate, while the monomer is mainly responsible for protonating methyl salicylate. Since the formation of the CI reagent (methanol clusters) can be controlled by simple variation of experimental parameters, the selectivity of the method can be easily adjusted to suit the targeted analyte. Performance is found to be independent of the choice of air or nitrogen as the sheath gas (and thus as the sample matrix) and this, together with the sensitivity and speed of the technique, make it promising for field studies.Keywords
This publication has 15 references indexed in Scilit:
- Atmospheric pressure chemical ionisation mass spectrometry for in vivo analysis of volatile flavour releaseFood Chemistry, 2000
- Use of Humidified Air in Optimizing APCI−MS Response in Breath AnalysisJournal of Agricultural and Food Chemistry, 2000
- Field air analysis with SPME deviceAnalytica Chimica Acta, 1999
- Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An UpdateJournal of Physical and Chemical Reference Data, 1998
- On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental researchInternational Journal of Mass Spectrometry and Ion Processes, 1998
- Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levelsChemical Society Reviews, 1998
- High-speed liquid chromatography/tandem mass spectrometry for the determination of drugs in biological samplesAnalytical Chemistry, 1986
- Sample introduction system for atmospheric pressure ionization mass spectrometry of nonvolatile compoundsAnalytical Chemistry, 1982
- Comparison of positive ions formed in nickel-63 and corona discharge ion sources using nitrogen, argon, isobutane, ammonia and nitric oxide as reagents in atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1976
- New picogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressureAnalytical Chemistry, 1973