Retinal nerve fibre layer polarimetry: histological and clinical comparison
Open Access
- 1 June 1998
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 82 (6) , 684-690
- https://doi.org/10.1136/bjo.82.6.684
Abstract
AIMS To compare histological thickness of the retinal nerve fibre layer in the primate with retardation measurements obtained in vivo using the Mark II Nerve Fiber Analyzer (NFA, Laser Diagnostic Technologies, San Diego, USA). METHODS Scanning laser polarimetry was performed on both eyes of a healthy anaesthetised adult primate (Macaca mulatta). The retinal nerve fibre layer thickness was measured in the eye with the best polarimetry image. A nerve fibre layer thickness map was scaled and aligned to a retardation map to permit correlation of retardation and thickness measurements. RESULTS Retinal nerve fibre layer thickness measurements could be satisfactorily aligned with corresponding retardation values at 216 locations. The overall correlation coefficient for nerve fibre layer thickness and retardation wasr = 0.70 (n = 216, p r = 0.76, n = 45, p r = 0.52, n = 26, p = 0.007 andr = 0.49, n = 86, p = r = 0.06, n = 67, p = 0.64). CONCLUSIONS In the primate eye, retinal nerve fibre layer thickness shows a positive correlation with retardation measurements obtained with the nerve fibre analyser. However, since the correlation coefficient varied around the optic disc, further evaluation of the device is advised before its routine clinical use.Keywords
This publication has 22 references indexed in Scilit:
- Clinically Detectable Nerve Fiber Atrophy Precedes the Onset of Glaucomatous Field LossArchives of Ophthalmology (1950), 1991
- Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer ThicknessArchives of Ophthalmology (1950), 1990
- Quantitative assessment of the optic nerve head with the laser tomographic scannerInternational Ophthalmology, 1989
- Visual Field and Retinal Nerve Fiber Layer Comparisons in GlaucomaArchives of Ophthalmology (1950), 1985
- The ganglion cell and cone distributions in the monkey's retina: Implications for central magnification factorsVision Research, 1985
- Evaluation of Nerve Fiber Layer AssessmentArchives of Ophthalmology (1950), 1984
- Nerve fiber layer of the primate retina: Thickness and glial contentVision Research, 1983
- Quantitative Studies of Retinal Nerve Fiber Layer DefectsArchives of Ophthalmology (1950), 1982
- Aging of the Optic NerveArchives of Ophthalmology (1950), 1980
- Thickness of the Retinal Nerve Fiber Layer in Primate EyesArchives of Ophthalmology (1950), 1980