IMPACT: Image‐based physiological artifacts estimation and correction technique for functional MRI
Open Access
- 24 July 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (2) , 344-353
- https://doi.org/10.1002/mrm.1197
Abstract
Functional MRI (fMRI) signal variation induced by respiratory and cardiac motion affects the activation signal and limits the accuracy of analysis. Current physiological motion correction methods require either synchronization with external monitoring of respiration and heartbeat, specialized pulse sequence design, ork‐space data. The IMage‐based Physiological Artifacts estimation and Correction Technique (IMPACT), which is free from these constraints, is described. When images are acquired fast enough to sample physiological motion without aliasing, respiratory and cardiac signals can be directly estimated from magnitude images. Physiological artifacts are removed by reordering images according to the estimated respiratory and cardiac phases and then subtracting the Fourier‐fitted variation from magnitude images. Compared with thek‐space–based method, this method can efficiently and effectively reduce the overall signal fluctuation in the brain and increase the activated area. With this new technique, physiological artifacts can be reduced using traditional fMRI pulse sequences, and existing data can be corrected and reanalyzed without additional experiments. Magn Reson Med 46:344–353, 2001.Keywords
This publication has 16 references indexed in Scilit:
- 3D spiral cardiac/respiratory ordered fMRI data acquisition at 3 TeslaMagnetic Resonance in Medicine, 1999
- Localization of Cardiac-Induced Signal Change in fMRINeuroImage, 1999
- Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR dataMagnetic Resonance in Medicine, 1996
- Reduction of physiological fluctuations in fMRI using digital filtersMagnetic Resonance in Medicine, 1996
- Functional connectivity in the motor cortex of resting human brain using echo‐planar mriMagnetic Resonance in Medicine, 1995
- Reduction of signal fluctuation in functional MRI using navigator echoesMagnetic Resonance in Medicine, 1994
- Artifacts due to stimulus correlated motion in functional imaging of the brainMagnetic Resonance in Medicine, 1994
- Processing strategies for time‐course data sets in functional mri of the human brainMagnetic Resonance in Medicine, 1993
- Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging.Proceedings of the National Academy of Sciences, 1992