A new technique to determine hydrogen excreted by gnotobiotic rats
Open Access
- 1 April 2000
- journal article
- research article
- Published by SAGE Publications in Laboratory Animals
- Vol. 34 (2) , 162-170
- https://doi.org/10.1258/002367700780457617
Abstract
A new system, that allowed the monitoring of hydrogen (H2) excretion by gnotobiotic rats without affecting their defined microbial status, was developed. The system consists of an isolator containing a chamber for an experimental animal, and a life-support system (LSS). with a sampling port outside the isolator connected to it. H2 accumulation in the system was measured by analysing a defined volume of gas after removal. H2 concentrations were determined with an electrochemical cell or by gas chromatography. To validate this technique, H2 excretion by germ-free (GF) and mono-associated rats fed a chemically defined diet was measured after oral application of lactulose. Mono-associated rats had been obtained by colonizing GF rats with a H2-producing Clostridium perfringens type A strain isolated from human faeces of a healthy volunteer. Application of 50 mg lactulose to the mono-associated rats resulted in a significant increase in H2 excretion. The net H2 excretion was 7.82±1.28 ml H2 in 12 h corresponding to a net maximal rate of 1.1±0.3 ml H2/h. In contrast, in experiments with GF rats, less than 0.13 ml H2 were detectable within 12 h. The technique presented is a useful tool for studying bacterial H2 metabolism in vivo under gnotobiotic conditions.Keywords
This publication has 0 references indexed in Scilit: