Comparisons of LET Distributions Measured in Low-Earth Orbit Using Tissue-Equivalent Proportional Counters and the Position-Sensitive Silicon-Detector Telescope (RRMD-III)
- 1 September 2001
- journal article
- research article
- Published by Radiation Research Society in Radiation Research
- Vol. 156 (3) , 310-316
- https://doi.org/10.1667/0033-7587(2001)156[0310:coldmi]2.0.co;2
Abstract
Doke, T., Hayashi, T. and Borak, T. B. Comparisons of LET Distributions Measured in Low-Earth Orbit Using Tissue-Equivalent Proportional Counters and the Position-Sensitive Silicon-Detector Telescope (RRMD-III). Radiat. Res. 156, 310–317 (2001).Determinations of the LET distribution, ϕ(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus ϕ(L) = ϕ(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of ϕ(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.Keywords
This publication has 21 references indexed in Scilit:
- Measurements of LET-distribution, dose equivalent and quality factor with the RRMD-III on the Space Shuttle Missions STS-84, -89 and -91Radiation Measurements, 2001
- Recent European measurements inside BiorackMutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, 1999
- LET distribution measurement with a new real-time radiation monitoring device-III onboard the Space Shuttle STS-84Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Dosimetry for Occupational Exposure to Cosmic RadiationRadiation Protection Dosimetry, 1997
- Radiation dosimetry measurements during U.S. space shuttle missions with the RME-IIIRadiation Measurements, 1994
- Tissue-Equivalent Proportional Counters in Radiation Protection Dosimetry: Expectations and Present StateRadiation Protection Dosimetry, 1992
- Dose rate, dose-equivalent rate, and quality factor in SLS-1International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1992
- Active dosimetric measurements on shuttle flightsInternational Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1992
- Measured microdosimetric spectra of energetic ion beams of Fe, Ar, Ne, and C: limitations of LET distributions and quality factors in space research and radiation effectsIEEE Transactions on Nuclear Science, 1991
- A Device for the Measurement of Dose as a Function of Specific IonizationRadiology, 1955