Dose response characteristics and basic dose distribution data for a polymerization-based dosemeter gel evaluated using MR.
- 1 January 2000
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 73 (865) , 58-65
- https://doi.org/10.1259/bjr.73.865.10721321
Abstract
A safe and reproducible mixing procedure for the manufacture of a polymerization-based dosemeter gel evaluated using MRI (PoMRI) is presented. The dose response, obtained by irradiating gel-filled vials with absorbed doses in the interval 0-20 Gy and evaluated with respect to 1/T2, was found to be linear in the interval 0-8 Gy, with a sensitivity of 0.211 s-1Gy-1 (r2 = 0.998) at 1.5 T. Evaluation of the same set of vials with respect to 1/T1 gave a sensitivity of 0.018 s-1Gy-1 (r2 = 0.960). PoMRI and diode data were compared for standard photon and electron treatment beams. A deviation of less than 3% was found between the two methods for central depth dose curves as well as dose profiles (2 mm for electrons in the steep dose gradient regions). The importance of the method used for background correction for the reliability of the results was also evaluated. Barex (with a wall thickness of 1.5 mm) was investigated for use as phantom material and found to be favourable compared with glass. The results obtained in this study show that PoMRI has excellent potential as a 3D detectorKeywords
This publication has 13 references indexed in Scilit:
- Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gelPhysics in Medicine & Biology, 1996
- Radiation therapy dosimetry using magnetic resonance imaging of polymer gelsMedical Physics, 1996
- The Effects of Cross-Link Density and Chemical Exchange on Magnetization Transfer in Polyacrylamide GelsJournal of Magnetic Resonance, Series B, 1996
- Correcting for rf inhomogeneities in multiecho pulse sequence MRI dosimetryMedical Physics, 1995
- Confirmation of target localization and dosimetry for 3D conformal radiotherapy treatment planning by MR imaging of a ferrous sulfate gel head phantomMedical Physics, 1995
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRIMagnetic Resonance Imaging, 1993
- Three-dimensional dose mapping from gamma knife treatment using a dosimeter gel and MR-imagingRadiotherapy and Oncology, 1992
- Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imagingPhysics in Medicine & Biology, 1984
- A protocol for the determination of absorbed dose from high‐energy photon and electron beamsMedical Physics, 1983