Retention Characteristics of Co+3, Fe+3, and Cu+24-(2-Pyridylazo)Resorcinol (PAR) Complexes on C-18 and Amino Silica Packings
- 1 August 1986
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 9 (10) , 2165-2183
- https://doi.org/10.1080/01483918608074141
Abstract
Chloroform extraction of Co-PAR, Fe-PAR, and Cu-PAR complexes in a pH 6.5 phosphate buffer implied the first two species were primarily monoanions, but the latter was a dianion. Examination of the literature and retention data of these complexes on C-18 and amino columns confirmed the more anionic nature of Cu-PAR. The Co+3 and Cu+2 complexes were slightly resolved from each other, but the Fe+3 complex was retained longer on the C-18 silica. In contrast, the Co+3 and Fe+3 complexes were not resolved, but the Cu+2 complex was well-retained on the weak anion exchange amino silica column. Use of short amino and C-18 columns in series provided a good separation of all three complexes. Detection of the metal complexes at 546 nm instead of 254 nm avoided interference by PAR and good detection limits were still maintained.This publication has 19 references indexed in Scilit:
- Liquid chromatographic separation of metals by on-column chelation with 4-(2-pyridylazo) resorcinolTalanta, 1985
- Liquid chromatography with electrochemical and or spectrophotometric detection for automated determination of lead, cadmium, mercury, cobalt, nickel and copperAnalytical Chemistry, 1984
- Precolumn chelation with 4-(2-pyridylazo)resorcinol for simultaneous determination of metal ions by liquid chromatographyAnalytical Chemistry, 1984
- Automated determination of nickel and copper by liquid chromatography with electrochemical and spectrophotometric detectionAnalytical Chemistry, 1983
- Determination of metals at trace levels via pre-column derivatization and nonpolar stationary-phase high-performance liquid chromatography with n-butyl-2-naphthylmethyldithiocarbamate complexesAnalytica Chimica Acta, 1982
- Simultaneous determination of copper, nickel, cobalt, chromium(VI), and chromium(III) by liquid chromatography with electrochemical detectionAnalytical Chemistry, 1982
- Extraction—spectrophotometric determination of copper(II) with 4-(2-pyridylazo)resorcinol and a long-chain quaternary ammonium saltAnalytica Chimica Acta, 1982
- Separation of 1,10-phenanthroline complexes of iron(II), nickel(II), and ruthenium(II) by reversed-phase, paired-ion chromatographyAnalytical Chemistry, 1980
- Extraction equilibria for the 4-(2-Pyridylazo)-Resorcinol-Nickel(II)-Quaternary-Ammonium salt systemAnalytica Chimica Acta, 1976
- Extraction of copper(II)-4-(2-pyridylazo)resorcinol complexes by tetraphenylphosphonium and arsonium chlorideJournal of Inorganic and Nuclear Chemistry, 1975