Integration of local and central laboratory functions in a worldwide multicentre study: Experience from the Hyperglycemia and Adverse Pregnancy Outcome (HAPO) Study
- 1 August 2006
- journal article
- research article
- Published by SAGE Publications in Clinical Trials
- Vol. 3 (4) , 397-407
- https://doi.org/10.1177/1740774506070695
Abstract
Background Measurement of glucose in multiple Field Laboratories requires rigorous standardization when patients and caregivers are masked, unless predefined thresholds are met. Local misclassification of participants at the thresholds can introduce recruitment bias and adversely affect the integrity of study findings. Purpose To describe the challenges and the approach to meeting them in measuring glucose, HbA1c, and C-peptide in the Hyperglycemia and Adverse Pregnancy Outcome (HAPO) Study. HAPO is an observational epidemiologic study of 25 000 pregnant women from 15 centres in 10 countries, designed to clarify unanswered questions on associations of maternal glycemia, less severe than overt diabetes mellitus, with risks of adverse pregnancy outcome. Methods Glucose tolerance (75 g two-hour OGTT) is assessed locally at 24-32 weeks’ gestation, with results masked if fasting and two-hour plasma glucose are ≤5.8 mmol/L and ≤11.1 mmol/L, respectively. For analysis of outcomes HAPO utilizes measurements of glucose, C-peptide, and HbA1c on frozen samples in a Central Laboratory; measurement of HbA1c on stored, frozen blood also creates special challenges. A common external quality assessment scheme was used to standardize glucose measurements between Field Centre and Central Laboratories before and during data collection. Results Agreement between Field Centres and the Central Laboratory in rates above the masking thresholds has been excellent (Kappa = 0.79, P < 0.001), with rates of 1.8 and 1.7% respectively. Percent technical error for Central Laboratory OGTT measurements of glucose, C-peptide, and HbA1c, were 2.0, 4.2, and 2.0, respectively. Limitations It is not possible to assess if comparable results could have been obtained with a less rigorous approach to standardization. Conclusions HAPO has been successful in ensuring comparability of glucose measurement between its Central Laboratory and Field Centre laboratories and in measuring its key metabolites with accuracy and precision. Recruitment bias based on glucose measurement has been avoided.This publication has 14 references indexed in Scilit:
- Strategies to Identify Adults at High Risk for Type 2 DiabetesDiabetes Care, 2005
- Estimating Laboratory Precision of Urinary Albumin Excretion and Other Urinary Measures in the International Study on Macronutrients and Blood PressureAmerican Journal of Epidemiology, 2004
- Discordance Rate, a New Concept for Combining Diagnostic Decisions with Analytical Performance Characteristics. 1. Application in Method or Sample System Comparisons and in Defining Decision Limitscclm, 2003
- The Hyperglycemia and Adverse Pregnancy Outcome (HAPO) StudyInternational Journal of Gynecology & Obstetrics, 2002
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- First‐trimester hemoglobin A1 and risk for major malformation and spontaneous abortion in diabetic pregnancyTeratology, 1989
- Incidence of Spontaneous Abortion among Normal Women and Insulin-Dependent Diabetic Women Whose Pregnancies Were Identified within 21 Days of ConceptionNew England Journal of Medicine, 1988
- Haemolysis affects insulin but not C-peptide immunoassayDiabetologia, 1987
- Clinical TrialsPublished by Oxford University Press (OUP) ,1986
- Fundamentals of AnesthesiaAnesthesiology, 1944