Sympathetic activity and haemodynamic variables during spinal analgesia in man
- 1 August 1987
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 31 (6) , 467-473
- https://doi.org/10.1111/j.1399-6576.1987.tb02605.x
Abstract
At present there is a lack of information concerning haemodynamic changes related to the degree of sympathetic blockade during spinal analgesia. In this investigation, involving 36 patients, changes in haemodynamic parameters were studied in 30 patients receiving spinal analgesia and in six patients having “sham spinal” analgesia. Three local anaesthetic solutions were used: bupivacaine without and with glucose and tetracaine with glucose. Skin conductance responses were used to evaluate changes in provoked sympathetic activity. It was found, as in previous studies, that a complete block of sympathetic activity in the foot was seen in only 60% of patients with an average analgesic level of T 4. A partial sympathetic blockade was registered up to and above the level of analgesia. In 25/30 cases only minor alterations in cardiac output, heart rate, stroke volume, mean arterial pressure and systemic vascular resistance were seen in spinal analgesia whose level reached on average T4–5. In five cases in whom analgesia reached T4‐3, mean arterial pressure fell≥30% with a well‐preserved cardiac output, but with complete sympathetic blockade up to T5, and in two cases also in the hand. Only minor differences were observed between the different anaesthetic solutions.Keywords
This publication has 41 references indexed in Scilit:
- Maternal Haemodynamic Changes during Caesarean Section: A Comparison of Epidural and General AnaesthesiaActa Anaesthesiologica Scandinavica, 1985
- Nausea and vomiting during spinal anaesthesiaAnaesthesia, 1984
- Measurement of Cardiac Stroke Volume During Cesarean Section: A Comparison Between Impedance Cardiography and the Dye Dilution TechniqueActa Anaesthesiologica Scandinavica, 1983
- Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancyActa Obstetricia et Gynecologica Scandinavica, 1983
- Measurement of stroke volume with impedance cardiographyClinical Physiology and Functional Imaging, 1982
- Measurements of Cardiac Stroke Volume in Various Body Positions in Pregnancy and during Caesarean Section: A Comparison Between Thermodilution and Impedance CardiographyScandinavian Journal of Clinical and Laboratory Investigation, 1979
- SIMULTANEOUS SYSTEMIC CARDIOVASCULAR AND RENAL HEMODYNAMIC MEASUREMENTS DURING HIGH SPINAL ANAESTHESIA IN NORMAL MANActa Anaesthesiologica Scandinavica, 1970
- Studies of Hemodynamic Changes in Humans Following Induction of Low and High Spinal AnesthesiaCirculation, 1952
- Studies of Hemodynamic Changes in Humans Following Induction of Low and High Spinal AnesthesiaCirculation, 1952