Endotracheal tubes in neonates: sonographic positioning.
- 1 July 1986
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 160 (1) , 262-263
- https://doi.org/10.1148/radiology.160.1.3520649
Abstract
Twenty-one real-time sonographic determinations of endotracheal tube tip position were performed in 16 neonates. Findings were compared with those from simultaneously obtained chest radiographs. Relation of the tube tip to the aortic arch provided a reliable method of determination of appropriate position. Optimal tube tip position was seen when the tube tip was 1 cm above the arch.This publication has 3 references indexed in Scilit:
- Prenatal X-Ray Exposure and Childhood Cancer in TwinsNew England Journal of Medicine, 1985
- Radiation doses to neonates requiring intensive careThe British Journal of Radiology, 1983