Accuracy of Pedicle Screw Placement in Lumbar Vertebrae
- 1 June 1996
- journal article
- Published by Wolters Kluwer Health in Spine
- Vol. 21 (11) , 1320-1324
- https://doi.org/10.1097/00007632-199606010-00008
Abstract
The location of pedicle screws (n = 42) in four human specimens of the lumbar spine and in 30 patients (n = 131 screws) after lumbar spinal fusion was assessed using computed tomography. To determine the accuracy of pedicle screw placement in lumbar vertebrae and the reproducibility and repeatability of the computed tomography examination. Failures in the placement of transpedicular screws for lumbar fusion are reported. The evaluation of such screws using computed tomography examination has not been investigated. After surgery, the specimens were dissected in transversal slices to observe macroscopically the location of the pedicle screw and to correlate these observations with the computed tomography images. All patients were examined by one observer. To determine the reproducibility and repeatability of the computed tomography examination, two observers studied computed tomography images of 12 patients (n = 58 screws) twice within 3 months. In the specimens, 10 screws were observed to penetrate the medial wall of the pedicle. This correlated fully with the images. In the patients' group, 40% of all screws penetrated the cortex of the vertebra. Of all screws, 29% penetrated the medial wall of the pedicle. From the computed tomography images, it appeared that a deviation of more than 6 mm medially was a high risk for nerve root damage. Three months after his first examination, Observer 1 documented a different position in three of 58 screws (kappa = 0.90). Observer 2 found a different position in eight screws (kappa = 0.65). The comparison between the reviews of the two observers showed a different opinion for the first evaluation, four disagreements (2-4 mm) and 17 disagreements (0-2 mm; kappa = 0.34), and for the second evaluation, four disagreements (2-4 mm) and 12 disagreements (0-2 mm; kappa = 0.43). Correct placement of transpedicular screws for spinal fusion seems to be more difficult than it looks. The computed tomography scanning is useful for differential diagnosis of postoperative radicular syndromes after lumbar transpedicular fixation.Keywords
This publication has 11 references indexed in Scilit:
- Lagekontrolle von Pedikelschrauben nach instrumentierter dorsaler Fusion der LendenwirbelsäuleZeitschrift für Orthopädie und ihre Grenzgebiete, 1992
- Results of spinal arthrodesis with pedicle screw-plate fixation.Journal of Bone and Joint Surgery, 1991
- Der Fixateur interne bei nicht-traumatischen Indikationen in der Wirbelsäulen-ChirurgieZeitschrift für Orthopädie und ihre Grenzgebiete, 1991
- Problems and Solutions of Pedicle Screw Plate Fixation of Lumbar SpineSpine, 1990
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990
- Posterior Transpedicular Zielke Instrumentation of the Lumbar SpineClinical Orthopaedics and Related Research, 1988
- Spinal Pedicle Fixation: Reliability and Validity of Roentgenogram-Based Assessment and Surgical Factors on Successful Screw PlacementSpine, 1988
- Analysis of the Morphometric Characteristics of the Thoracic and Lumbar PediclesSpine, 1987
- An Internal Fixator for Posterior Application to Short Segments of the Thoracic, Lumbar, or Lumbosacral Spine Design and TestingPublished by Wolters Kluwer Health ,1986
- Fusion of the Lumbar and Sacral Spine by Internal Fixation with Screw PlatesClinical Orthopaedics and Related Research, 1986