Pulse wave analysis and pulse wave velocity
Top Cited Papers
- 1 March 2003
- journal article
- review article
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 21 (3) , 463-472
- https://doi.org/10.1097/00004872-200303000-00004
Abstract
The study of the pulse using the technique of applanation tonometry is undergoing a resurgence with the development of new computerized equipment. We aim here to present a critical review of the uses, potential uses, strengths and weaknesses of the technique of applanation tonometry for the assessment of augmentation index and pulse wave velocity. We will review the technique of applanation tonometry, the physiological factors affecting pulse wave velocity and pulse wave analysis, the changes in pulse wave velocity and pulse wave analysis with pharmacological interventions, and the use of the technique of applanation tonometry as a prognostic tool. We conclude that, although the technique of applanation tonometry initially seems promising, several pertinent issues need to be addressed before it can be used reliably as a clinical or research tool. Importantly, use of the technique of applanation tonometry to derive the central waveform from non-invasively acquired peripheral data needs to be validated prospectively.Keywords
This publication has 84 references indexed in Scilit:
- Noninvasive Assessment of the Digital Volume PulseHypertension, 2000
- Genesis of the normal and abnormal arterial pulseCurrent Problems in Cardiology, 2000
- Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometryIEEE Transactions on Biomedical Engineering, 1999
- Functional characterization of endothelin receptors in hypertensive resistance vesselsJournal Of Hypertension, 1999
- Estimation of Central Aortic Pressure Waveform by Mathematical Transformation of Radial Tonometry PressureCirculation, 1997
- Factors Associated With Survival to 75 Years of Age in Middle-aged Men and WomenArchives of internal medicine (1960), 1996
- Noninvasive Pulse Wave Analysis for the Early Detection of Vascular DiseaseHypertension, 1995
- Haemodynamic basis for the development of left ventricular failure in systolic hypertension and for its logical therapyJournal Of Hypertension, 1995
- An analysis of the relationship between central aortic and peripheral upper limb pressure waves in manEuropean Heart Journal, 1993
- Left Ventricular Mass and Incidence of Coronary Heart Disease in an Elderly CohortAnnals of Internal Medicine, 1989