Testing the limitations of 2-D companding for strain imaging using phantoms
- 1 July 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 45 (4) , 1022-1031
- https://doi.org/10.1109/58.710585
Abstract
Companding may be used as a technique for generating low-noise strain images. It involves warping radio-frequency echo fields in two dimensions and at several spatial scales to minimize decorrelation errors in correlation-based displacement estimates. For the appropriate experimental conditions, companding increases the sensitivity and dynamic range of strain images without degrading contrast or spatial resolution significantly. In this paper, we examine the conditions that limit the effectiveness of 2-D local companding through a series of experiments using phantoms with tissue-like acoustic and elasticity properties. We found that strain noise remained relatively unchanged as the applied compression increased to 5% of the phantom height, while target contrast increased in proportion to the compression. Controlling the image noise at high compressions improves target visibility over the broad range induced in elastically heterogeneous media, such as biological tissues. Compressions greater than 5% introduce large strains and complex motions that reduce the effectiveness of companding. Control of boundary conditions and ultrasonic data sampling rates is critical for a successful implementation of our algorithms.Keywords
This publication has 17 references indexed in Scilit:
- Phantom materials for elastographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Ultrasonic measurement of glomerular diameters in normal adult humansUltrasound in Medicine & Biology, 1996
- Noise reduction in elastograms using temporal stretching with multicompression averagingUltrasound in Medicine & Biology, 1996
- Elasticity imaging for early detection of renal pathologyUltrasound in Medicine & Biology, 1995
- Internal displacement and strain imaging using ultrasonic speckle trackingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1994
- Reduction of Image Noise in ElastographyUltrasonic Imaging, 1993
- A novel method for angle independent ultrasonic imaging of blood flow and tissue motionIEEE Transactions on Biomedical Engineering, 1991
- A Model For Dynamic Texture Analysis In Two-Dimensional Echocardiograms Of The MyocardiumPublished by SPIE-Intl Soc Optical Eng ,1987
- Estimation of time delay in the presence of source or receiver motionThe Journal of the Acoustical Society of America, 1977
- Average magnitude difference function pitch extractorIEEE Transactions on Acoustics, Speech, and Signal Processing, 1974