The relation between packing and reopening in coiled intracranial aneurysms: a prospective study
- 1 September 2005
- journal article
- clinical trial
- Published by Springer Nature in Neuroradiology
- Vol. 47 (12) , 942-945
- https://doi.org/10.1007/s00234-005-1446-9
Abstract
We evaluated prospectively the relation between packing and reopening in coiled intracranial aneurysms. Packing, defined as the ratio between the volume of inserted coils and volume of the aneurysm expressed as percentage, was calculated for 82 intracranial aneurysms treated with detachable coils. Aneurysm volume was assessed from 3D angiography. Reopening of the aneurysmal lumen at the 6-month follow-up angiography was dichotomized into present or absent. We assessed whether packing above 24% protected against reopening. Twenty-three of 82 aneurysms (28%) showed reopening. Reopening was caused by compaction in 20 aneurysms and by partial thrombosis, undetected at the time of initial treatment in three aneurysms. Three of 29 aneurysms (10%) with a packing of more than 24% showed reopening. These three aneurysms contained partially intraluminal thrombosis undetected at the time of treatment. We conclude that in coiled intracranial aneurysms packing above 24% protects against reopening by compaction in non-thrombosed aneurysms. Since intraluminal thrombosis may go undetected at the time of treatment, follow-up angiography is still warranted in aneurysms with packing densities greater than 24%.Keywords
This publication has 13 references indexed in Scilit:
- MR Angiography at 3T versus Digital Subtraction Angiography in the Follow-up of Intracranial Aneurysms Treated with Detachable Coils2005
- Coil Thickness and Packing of Cerebral Aneurysms: A Comparative Study of Two Types of Coils2005
- Additional Coiling of Previously Coiled Cerebral Aneurysms: Clinical and Angiographic Results2004
- Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated with CoilsRadiology, 2004
- Aneurysm Packing with HydroCoil Embolic System versus Platinum Coils: Initial Clinical Experience2004
- Increasing the Packing of Small Aneurysms with Complex-Shaped Coils: An In Vitro Study2003
- Endovascular Treatment of Ruptured Intracranial Aneurysms with Detachable Coils: Long-term Clinical and Serial Angiographic ResultsRadiology, 2003
- Endovascular Occlusion of Intracranial Aneurysms with Guglielmi Detachable Coils: Correlation Between Coil Packing Density and Coil CompactionActa Neurochirurgica, 2001
- Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleedingJournal of Neurosurgery, 1999
- Treatment of Intracranial Aneurysms by Embolization with CoilsStroke, 1999