Development of a computer‐controlled tensiometer for real‐time measurements of tension in tubular organs
- 1 April 1999
- journal article
- research article
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 11 (2) , 109-118
- https://doi.org/10.1046/j.1365-2982.1999.00144.x
Abstract
A computer-controlled tensiometer for studying wall tension in tubular organs has been developed. The system consisted of a probe with an inflatable balloon, an impedance planimeter, pressure transducer and amplifier, a pump with RS232 interface and a PC with dedicated software. Circumferential wall tension was computed in real time from pressure and cross-sectional area measurements (tension measurement mode). Wall tension can be maintained on a preset level or be changed as a step or ramp function by a feedback control of the infusion/withdrawal pump (tension control mode). A software regulator adjusted the volume rate (low volume rate when the computed tension was close to the preset value) to minimize overshoot and oscillation. Validation tests were performed and the technique was applied in the human oesophagus. Volume- and tension-controlled balloon distensions elicited secondary peristalsis of increasing intensity that was decreased significantly by the antimuscarinic agent Hyoscine butyl bromide. In tension control mode Hyoscine butyl bromide caused oesophageal relaxation, i.e. CSA to increase and pressure to decay. Furthermore, pronounced pressure relaxation and tension relaxation were observed during volume-controlled distension after administration of Hyoscine butyl bromide.Keywords
This publication has 13 references indexed in Scilit:
- Incremental elastic modulus - a challenge to complianceInternational Journal of Colorectal Disease, 1997
- Impedance Planimetric Characterization of Esophagus in Systemic Sclerosis Patients with Severe Involvement of EsophagusDigestive Diseases and Sciences, 1997
- Biomechanics of the gastrointestinal tractNeurogastroenterology & Motility, 1996
- Measurement of human esophageal tone in vivoGastroenterology, 1993
- Biomechanical wall properties of the human rectum. A study with impedance planimetry.Gut, 1993
- Biomechanical wall properties in the isolated perfused porcine duodenum: an experimental study using impedance planimetryNeurogastroenterology & Motility, 1992
- Impedance Planimetry: A New Approach to Biomechanical Intestinal Wall PropertiesDigestive Diseases, 1991
- New probe for measurement of related values of cross-sectional area and pressure in a biological tubeMedical & Biological Engineering & Computing, 1986