Performance Study of PETT VI, a Positron Computed Tomograph with 288 Cesium Fluoride Detectors
- 1 February 1982
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 29 (1) , 529-533
- https://doi.org/10.1109/tns.1982.4335901
Abstract
The first positron computed tomography system with cesium fluoride scintillation detectors, PETT VI, has been developed. The system provides 7 slice images with 4 detector rings (57 cm). Performances of the system are discussed and clarified based on experimental data. Adoption of CsF detectors decrease the random coincidence rate by achieving a short coincidence timing resolution. The timing resolution of a pair of detector heads is 1.5 nsec FWHM and 3.0 nsec FWTM. After a preliminary timing alignment of 288 detectors, the coincidence window width (2τ) of 11 nsec or wiider has yielded maximum coincidence sensitivity, and operation at 5.9 nsec has given 91% of maximum. The full sensitivity for a cyclindrical uniform phantom (20 cm dia × 13 cm) is 354 kcps/microCi/cc/7 slices in a low resolution mode (intrinsic resolution at center is 11.7 mm FWHM). In a high resolution mode (7.1 mm), it is 31% of the full sensitivity. Coincidence rates ratio, [random/(true + scattered)], in the low resolution mode, is 0.16 α with 5.9 nsec window width inside the phantom images reconstructed without a random correction, where α is activity density (microCi/cc). The ratio is 1/3 of that obtained when operating at 20 nsec. Scattered coincidence fraction at the center of the phantom images, without the random correction process, is 9% of the [true + scattered].Keywords
This publication has 17 references indexed in Scilit:
- PETT VIJournal of Computer Assisted Tomography, 1982
- Photon Time-of-Flight-Assisted Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- One Dimensional Scintillation Cameras for Positron Ect Ring DetectorsIEEE Transactions on Nuclear Science, 1981
- A New Sampling Scheme for the Ring Positron Camera: Dichotomic Ring SamplingIEEE Transactions on Nuclear Science, 1981
- Monte Carlo Calculations of the Detection Efficiency of Arrays of Nai(Tl), Bgo, Csf, Ge, and Plastic Detectors for 511 Kev PhotonsIEEE Transactions on Nuclear Science, 1981
- POTENTIAL ADVANTAGES OF A CESIUM FLUORIDE SCINTILLATOR FOR A TIME-OF-FLIGHT POSITRON CAMERAJournal of Computer Assisted Tomography, 1980
- Positologica: A Positron ECT Device with a Continuously Rotating Detector RingIEEE Transactions on Nuclear Science, 1980
- Use of Position Sensitive Detectors in Positron ImagingIEEE Transactions on Nuclear Science, 1980
- Cesium Fluoride: A New Detector for Positron Emission TomographyIEEE Transactions on Nuclear Science, 1980
- Positome II: A High Efficiency Positron Imaging Device for Dynamic Brain StudiesIEEE Transactions on Nuclear Science, 1979