Mode-Stirred Chamber Calibration Factor, Relaxation Time, and Scaling Laws
Open Access
- 1 December 1985
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. IM-34 (4) , 573-580
- https://doi.org/10.1109/tim.1985.4315406
Abstract
In this paper, single-mode cavity theory relating cavity Q, stored energy, and relaxation time is applied to mode-stirred chamber (MSC) operation. It is shown that a calibration factor for average power density, defined in terms of stored energy density, can be determined solely from a relaxation time measurement, for which a suitable measurement technique is also shown. A possible definition of minimum operating frequency for an MSC is also defined in terms of parameters that can easily be measured during normal chamber operation. Finally, an attempt is made to show how the derived and measured results apply to MSC operation and design.Keywords
This publication has 1 reference indexed in Scilit:
- Performance and Analysis of a Reverberating Enclosure with Variable GeometryIEEE Transactions on Electromagnetic Compatibility, 1980