Local Continuity of Myocardial Blood Flow Studied by Monochromatic Synchrotron Radiation–Excited X-ray Fluorescence Spectrometry
- 1 June 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 76 (6) , 1088-1100
- https://doi.org/10.1161/01.res.76.6.1088
Abstract
We have developed a monochromatic synchrotron radiation–excited system for two-dimensional mapping of x-ray fluorescence evoked from heavy element–loaded microspheres, which can evaluate myocardial blood flow in small contiguous regions with a small methodological error: 10.8±2.4% of the average of difference of the dual flow for 7- to 10-mg myocardial tissue (4 dogs). The fractal D value obtained from the slope of the log relative dispersion–log mass plot was 1.21±0.08 for a voxel size of 7 to 1260 mg (5 dogs) and that for a voxel size of 2.5 to 40 mg (1.12±0.06) was smaller than that for a voxel size of 40 to 1280 mg (1.25±0.14, P <.05, ANOVA, 4 dogs). The distance–correlation coefficient relation for paired myocardial regions was attenuated (correlation analysis), and the correlation coefficients between the original grouping and the two aggregates of the adjacent regions were dissociated (extended correlation analysis) under reduction of coronary perfusion pressure (6 dogs). Suppression of myocardial contraction with lidocaine (3 dogs) and vasodilation with adenosine partly improved the distance–correlation coefficient relation under reduced coronary perfusion pressure. Thus, an x-ray fluorescence system designed for precise flow measurement shows that the fractal nature of local flow distribution can be extended into regions smaller than previously reported, that in these regions the flow becomes more homogeneous, and that the self similarity and continuity of local flow are attenuated by the reduction of coronary perfusion pressure and improved by contractile suppression and coronary vasodilation.Keywords
This publication has 17 references indexed in Scilit:
- Increased responsiveness of left ventricular apical myocardium to adrenergic stimuliCardiovascular Research, 1993
- Regional Blood Flow Measurement with Non-Radioactive Microspheres by X-ray Fluorescence SpectrometryPublished by Springer Nature ,1993
- Fractal correlation in heterogeneous systemsPhysica D: Nonlinear Phenomena, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Energy dispersive X-ray fluorescence analysis with synchrotron radiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1985
- A method for measuring X-ray mass-absorption coefficients of geological materialsChemical Geology, 1980
- Spatial and temporal heterogeneity of left ventricular perfusion in awake dogsAmerican Heart Journal, 1977
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977
- Microvasculature of the dog left ventricular myocardiumMicrovascular Research, 1974
- Total and Regional Myocardial Blood Flow Measurements with 25µ, 15µ, 9µ, and Filtered 1-10µ Diameter Microspheres and Antipyrine in Dogs and SheepCirculation Research, 1974