Disturbances of motor output in a cat hindlimb muscle after acute dorsal spinal hemisection
- 1 January 1988
- journal article
- research article
- Published by Springer Nature in Experimental Brain Research
- Vol. 71 (2) , 377-387
- https://doi.org/10.1007/bf00247497
Abstract
Summary Force and electromyogram (EMG) responses of the medial gastrocnemius muscle were assessed during isometric contractions in 8 decerebrate cat preparations, before and after acute dorsal hemisection of the spinal cord at the T12 level. The measures derived included the relation between static force and mean rectified EMG, the EMG amplitude distribution, EMG power spectral density, and force power spectral density. Our findings were that the spinal lesion induced modifications in the shape of the EMG amplitude distribution, a substantial increase in mean rectified EMG per unit force, and increases in EMG spectral power and force spectral power over a broad band of frequencies. In 7/8 preparations, there was disproportionate enhancement of EMG spectral power below 40 Hz, with a commensurate reduction in the EMG mean power frequency (MPF) in 6 of these 7 cases. Recordings of motoneuron discharge from 9 decerebrate preparations taken before and after the spinal hemisection revealed that the lesion-induced changes in EMG and force power spectra were accompanied by lower mean discharge rates, and by a compression of the range of recruitment force. These changes in motoneuron rate and recruitment were probably responsible for the changes in EMG and force measures, especially for the relative increase in low-frequency EMG power. If these acute disturbances of motoneuron rate and recruitment persist in chronic human neurological disorders, they represent an important and largely unrecognized source of muscular weakness and increased fatigability.Keywords
This publication has 17 references indexed in Scilit:
- Reflex actions of muscle afferents on fusimotor innervation in decerebrated cats: an assessment of beta contributionsExperimental Brain Research, 1985
- The effects of motor unit synchronization on the power spectrum of the electromyogramBiological Cybernetics, 1984
- Relation between isometric force and stimulus rate in cat's hindlimb motor units of different twitch contraction timeExperimental Brain Research, 1983
- Abnormal force--EMG relations in paretic limbs of hemiparetic human subjects.Journal of Neurology, Neurosurgery & Psychiatry, 1981
- Mechanisms of the clasp-knife reflex studied in an animal modelExperimental Brain Research, 1979
- The relation between the surface electromyogram and muscular force.The Journal of Physiology, 1975
- SPASTICITY, DECEREBRATE RIGIDITY AND THE CLASP-KNIFE PHENOMENON: AN EXPERIMENTAL STUDY IN THE CATBrain, 1972
- The effects of length and stimulus rate on tension in the isometric cat soleus muscleThe Journal of Physiology, 1969
- Firing patterns of gastrocnemius motor units in the decerebrate catThe Journal of Physiology, 1968
- The isometric responses of mammalian musclesThe Journal of Physiology, 1930