Comparison of calibration methods for respiratory inductive plethysmography in infants
- 1 November 1987
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 63 (5) , 1853-1861
- https://doi.org/10.1152/jappl.1987.63.5.1853
Abstract
In infants under the age of 6 mo respiratory inductive plethysmograph (RIP)-calculated tidal volumes (VT) were compared with simultaneously measured volumes using a pneumotachograph (PNT) to 1) assess whether using multiple points (MP) along the inspiratory profile of a breath is superior to using only VT when calculating volume-motion (VM) coefficients, 2) verify the assumption of independent contributions of the abdomen and rib cage to VT, which was accomplished by extending the normal RIP model to include a term representing interaction between these two compartments, and 3) investigate whether VM coefficients are sleep-state dependent. Neither use of multiple points nor inclusion of the interacting term improved the performance of the RIP over that observed using a simple two-compartment model with VT measurements. However, VM coefficients obtained during quiet sleep (QS) were not reliable when used during rapid-eye-movement (REM) sleep, suggesting that coefficients obtained during one sleep state may not be applicable to another state where there is a substantial change in the relative abdominal/rib cage contributions to VT.This publication has 13 references indexed in Scilit:
- EFFECTS OF A FACE MASK AND PNEUMOTACHOGRAPH ON BREATHING IN SLEEPING INFANTSPublished by Elsevier ,1983
- POSTURAL CHANGES IN RIB CAGE AND ABDOMINAL VOLUME-MOTION COEFFICIENTS AND THEIR EFFECT ON THE CALIBRATION OF A RESPIRATORY INDUCTANCE PLETHYSMOGRAPHPublished by Elsevier ,1983
- Changes in Respiratory Pattern Resulting from the Use of a Facemask to Record Respiration in Newborn InfantsPediatric Research, 1982
- VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY USING DIFFERENT CALIBRATION PROCEDURESPublished by Elsevier ,1982
- CALIBRATION OF RESPIRATORY INDUCTION PLETHYSMOGRAPHY (RESPITRACE) IN INFANTSPublished by Elsevier ,1982
- Noninvasive ventilatory monitoring by respiratory inductive plethysmography in conscious sheepJournal of Applied Physiology, 1981
- RESPIRATORY INDUCTION PLETHYSMOGRAPHY (RESPITRACE) - AN EVALUATION OF ITS USE IN THE INFANTPublished by Elsevier ,1981
- NON-INVASIVE MEASUREMENT OF VENTILATION DURING EXERCISE USING A RESPIRATORY INDUCTIVE PLETHYSMOGRAPH .1.Published by Elsevier ,1980
- Computer-aided measurement of breath volume and time components using magnetometersJournal of Applied Physiology, 1978
- Measurement of the separate volume changes of rib cage and abdomen during breathingJournal of Applied Physiology, 1967