Effects on the bispectral index during medium‐high dose fentanyl induction with or without propofol supplement
- 1 August 2000
- journal article
- clinical trial
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 44 (7) , 807-811
- https://doi.org/10.1034/j.1399-6576.2000.440707.x
Abstract
Background: The search for a drug‐independent monitor to determine depth of anaesthesia and hypnosis continues. The bispectral analysis (BIS) of the EEG correlates well with the clinical dose–response of hypnotic drugs during induction, but the effect on BIS of an opiate induction, as for coronary bypass surgery, is not known. Methods: Fourteen patients scheduled for elective coronary bypass surgery were studied. BIS was recorded during induction in 7 patients receiving 10 μg/kg fentanyl without any hypnotic agent and in 7 patients receiving 0.5 mg/kg propofol before the fentanyl dose. Results: The effect of fentanyl was very variable both regarding BIS and clinical response. Five of the 7 patients that received only fentanyl lost their response to verbal command within 8 min. BIS values at loss of response varied between 45 and 94. One patient remained awake with BIS 43. All 7 patients receiving propofol before the fentanyl dose lost their response to verbal command within 5 min. BIS values at the time for loss of response varied between 78 and 98. Conclusion: Loss of response to verbal command when a medium‐high dose of fentanyl is used for induction cannot be distinguished from wakefulness with adequate sensitivity by BIS. The current BIS algorithm seems not to accurately reflect the hypnotic effects of fentanyl.Keywords
This publication has 12 references indexed in Scilit:
- Nitrous oxide does not alter bispectral index: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesiaBritish Journal of Anaesthesia, 1999
- Hypnotic endpoints vs. the bispectral index,95% spectral edge frequency and median frequency during propofol infusion with or without fentanylPublished by Wolters Kluwer Health ,1999
- The Effect of the Interaction of Propofol and Alfentanil on Recall, Loss of Consciousness, and the Bispectral IndexAnesthesia & Analgesia, 1998
- Bispectral EEG Index during Nitrous Oxide AdministrationAnesthesiology, 1998
- Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by SevofluraneAnesthesiology, 1998
- Bispectral Analysis of the Electroencephalogram Predicts Conscious Processing of Information during Propofol Sedation and HypnosisAnesthesiology, 1998
- A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic EffectAnesthesia & Analgesia, 1997
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Altersabhängige Korrelation zwischen EEG-Parametern und zunehmender Narkosetiefe unter Propofol Effekte von FentanylDer Anaesthesist, 1996