Method for Measuring Magnetostriction Corrected for Initial Domain Distribution and its Application to Nickel and Iron
- 1 February 1958
- journal article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 29 (2) , 182-184
- https://doi.org/10.1063/1.1723062
Abstract
A method has been developed for the measurement of magnetostrictive strain that overcomes the effect of initial domain distribution in isotropic materials. A cubic specimen is used, placed between two iron rods of the same cross section. The combination is put along the common axis of two like solenoids connected in series. Strain is measured with a resistance strain gauge, once parallel to the magnetic field, and a second time normal to the field after the specimen has been rotated 90°. At saturation the algebraic difference gives 3/2 of the saturation magnetostriction. Use of the difference eliminates or reduces a number of experimental errors in addition to that arising from nonrandomness of initial domain distribution. The method has been applied to grade A nickel and armco iron.This publication has 5 references indexed in Scilit:
- Magnetostriction and Magnetomechanical EffectsReports on Progress in Physics, 1955
- Magnetic Crystal Anisotropy and Magnetostriction of Iron-Nickel AlloysPhysical Review B, 1953
- New techniques and results in the measurement of magnetostrictionJournal de Physique et le Radium, 1951
- ber die Magnetostriktion von ferromagnetischen EllipsoidenThe European Physical Journal A, 1934
- Über Hysteresiserscheinungen bei der MagnetostriktionAnnalen der Physik, 1931