Context. A1c levels are widely used to assess quality of diabetes care provided by health care systems. Currently, cross‐sectional measures are commonly used for such assessments.Objective. To study within‐patient longitudinal changes in A1c levels at Veterans Health Administration (VHA) facilities as an alternative to cross‐sectional measures of quality of diabetes care.Design. Longitudinal study using institutional data on individual patient A1c level over time (October 1, 1998–September 30, 2000) with time variant and invariant covariates.Setting. One hundred and twenty‐five VHA facilities nationwide, October 1, 1998–September 30, 2000.Patients. Diabetic veteran users with A1c measurement performed using National Glycosylated Hemoglobin Standardization Project certified A1c lab assay methods.Exposures. Characteristics unlikely to reflect quality of care, but known to influence A1c levels, demographics, and baseline illness severity.Main Outcome Measure. Monthly change in A1c for average patient cared for at each facility.Results. The preponderance of facilities showed monthly declines in within‐patient A1c over the study period (mean change of −0.0148 A1c units per month, range −0.074 to 0.042). Individual facilities varied in their monthly change, with 105 facilities showing monthly declines (70 significant at .05 level) and 20 showing monthly increases (5 significant at .05 level). Case‐mix adjustment resulted in modest changes (mean change of −0.0131 case‐mix adjusted A1c units per month, range −0.079 to 0.043). Facilities were ranked from worst to best, with attached 90 percent confidence intervals. Among the bottom 10 ranked facilities, four remained within the bottom decile with 90 percent confidence.Conclusions. There is substantial variation in facility‐level longitudinal changes in A1c levels. We propose that evaluation of change in A1c levels over time can be used as a new measure to reflect quality of care provided to populations of individuals with chronic disease.Keywords
This publication has 23 references indexed in Scilit:
- Cross-Sectional versus Longitudinal Performance Assessments in the Management of DiabetesMedical Care, 2004
- Effect of the Transformation of the Veterans Affairs Health Care System on the Quality of CareNew England Journal of Medicine, 2003
- Sulfonylurea InadequacyDiabetes Care, 2002
- Identifying Persons with Diabetes Using Medicare Claims DataAmerican Journal of Medical Quality, 1999
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- Influence of Cardiac-Surgery Performance Reports on Referral Practices and Access to Care — A Survey of Cardiovascular SpecialistsNew England Journal of Medicine, 1996
- Kinetics of HbA1c, Glycated Albumin, and Fructosamine and Analysis of Their Weight Functions Against Preceding Plasma Glucose LevelDiabetes Care, 1995
- Adapting a clinical comorbidity index for use with ICD-9-CM administrative databasesJournal of Clinical Epidemiology, 1992
- A new method of classifying prognostic comorbidity in longitudinal studies: Development and validationJournal of Chronic Diseases, 1987
- Longitudinal data analysis using generalized linear modelsBiometrika, 1986