Peristent Remodeling and Neointimal Suppression 2 Years After Polymer-Based, Paclitaxel-Eluting Stent Implantation
- 20 December 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 112 (25) , 3876-3883
- https://doi.org/10.1161/circulationaha.105.558601
Abstract
Background— The purpose of this study was to evaluate long-term vascular responses as long as 2 years after implantation of polymer-based, paclitaxel-eluting stents in contrast to uncoated stents. Methods and Results— TAXUS II is a randomized, double-blind trial comparing slow-release (SR) and moderate-release (MR) TAXUS stents with bare-metal control stents (BMSs). One hundred sixty-one event-free patients (SR, 43; MR, 41; and BMS, 77) underwent serial intravascular ultrasound (IVUS) analysis after the procedure and at 6 months and 2 years. At 2 years, neointimal responses continued to be significantly suppressed in the SR and MR groups when compared with the BMS group (BMS, 1.49±1.12 mm 2 ; SR, 0.94±0.76 mm 2 [ P =0.004]; and MR, 1.06±0.90 mm 2 [ P =0.02]). Between 6 months and 2 years, the BMS group showed compaction of the neointima (Δ, −0.22±1.05 mm 2 [ P =0.08]). In contrast, both the SR and MR groups exhibited an increase (Δ SR, 0.30±0.76 mm 2 ( P =0.01); MR, 0.41±0.94 mm 2 [ P =0.009]). Between 6 months and 2 years, the initial increase in plaque outside the stent regressed in the BMS and SR groups to levels comparable to those after the procedure, whereas expansive remodeling partially regressed in the MR group (Δ between after the procedure and 2 years BMS, −0.34±1.28 mm 2 [ P =0.05]; SR, −0.02±1.40 mm 2 [ P =0.93]; MR, 0.32±1.56 mm 2 [ P =0.27]). Conclusions— The 2-year follow-up demonstrates that neointimal suppression was dose independent and that this effect was still sustained at 2 years. However, the increase in area outside the stent seen at 6 months regressed to different extents in a dose-dependent manner at 2 years.Keywords
This publication has 18 references indexed in Scilit:
- Four-Year Angiographic and Intravascular Ultrasound Follow-Up of Patients Treated With Sirolimus-Eluting StentsCirculation, 2005
- Incomplete Stent Apposition After Implantation of Paclitaxel-Eluting Stents or Bare Metal StentsCirculation, 2005
- Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary modelCardiovascular Research, 2004
- Five-Year Follow-Up After Intracoronary Gamma Radiation Therapy for In-Stent RestenosisCirculation, 2004
- Randomized Study to Assess the Effectiveness of Slow- and Moderate-Release Polymer-Based Paclitaxel-Eluting Stents for Coronary Artery LesionsCirculation, 2003
- Regional Remodeling as the Cause of Late Stent MalappositionCirculation, 2003
- Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data AnalysisCirculation, 2002
- Two-Year Angiographic Follow-Up of Intracoronary Sr90 Therapy for Restenosis Prevention After Balloon AngioplastyCirculation, 2002
- Five-Year Clinical Follow-Up After Intracoronary RadiationCirculation, 2002
- Chronic arterial responses to stent implantation: A serial intravascular ultrasound analysis of palmaz-schatz stents in native coronary arteriesJournal of the American College of Cardiology, 1996