Does intensity windowing improve the detection of simulated calcifications in dense mammograms?
Open Access
- 1 May 1997
- journal article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 10 (2) , 79-84
- https://doi.org/10.1007/BF03168559
Abstract
This study attempts to determine whether intensity windowing (IW) improves detection of simulated calcifications in dense mammograms. Clusters of five simulated calcifications were embedded in dense mammograms digitized at 50-μm pixels, 12 bits deep. Film images with no windowing applied were compared with film images with nine different window widths and levels applied. A simulated cluster was embedded in a realistic background of dense breast tissue, with the position of the cluster varied. The key variables involved in each trial included the position of the cluster, contrast level of the cluster, and the IW settings applied to the image. Combining the ten IW conditions, four contrast levels and four quadrant positions gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 160 backgrounds. The entire experiment consisted of 800 trials. Twenty student observers were asked to detect the quadrant of the image in which the mass was located. There was a statistically significant improvement in detection performance for clusters of calcifications when the window width was set at 1024 with a level of 3328, and when the window width was set at 1024 with a level of 3456. The selected IW settings should be tested in the clinic with digital mammograms to determine whether calcification detection performance can be improved.Keywords
This publication has 13 references indexed in Scilit:
- A method for determination of optimal image enhancement for the detection of mammographic abnormalitiesJournal of Digital Imaging, 1994
- Comparison of Bilateral-Subtraction and Single-Image Processing Techniques in the Computerized Detection of Mammographic MassesInvestigative Radiology, 1993
- Portal film enhancement: Technique and clinical utilityInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Computerized detection of masses in digital mammograms: Analysis of bilateral subtraction imagesMedical Physics, 1991
- Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammographyMedical Physics, 1987
- Digital MammographyInvestigative Radiology, 1987
- Mammographic microcalcifications: detection with xerography, screen-film, and digitized film display.Radiology, 1986
- Enhanced image mammographyAmerican Journal of Roentgenology, 1983
- Lesion conspicuity, structured noise, and film reader errorAmerican Journal of Roentgenology, 1976
- The Influence of Structured Noise on the Detection of Radiologic AbnormalitiesInvestigative Radiology, 1974