Characterization of a Cross-Reactive Electronic Nose with Vapoluminescent Array Elements
- 26 April 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (11) , 2547-2555
- https://doi.org/10.1021/ac011255d
Abstract
A three-channel cross-reactive sensor array based on vapoluminescent platinum(II) double salt materials has been characterized. Two arrays were studied, one consisting of [Pt(CN-cyclododecyl)4][Pt(CN)4] (1), [(phen)Pt(CN-cyclohexyl)2][Pt(CN)4] (2), and [Pt(CN-n-tetradecyl)4][Pt(CN)4] (3) materials, where phen = 1,10-phenanthroline, and a second array that has compound 3 replaced by the mixed double salt material [(phen)Pt(CN-cyclododecyl)Cl)]2[(phen)Pt(CN-cyclododecyl)2]2[Pt(CN)4]3 (4). Compounds 2, 3 and 4 are characterized here for the first time. Inclusion of solvent vapors into these materials often leads to dramatic shifts in their solid-state absorption and luminescence spectra. In these studies the arrays were exposed to a set of 10 test solvent vapors to determine the ability of each cross-reactive array to give reproducible vapoluminescent spectra characteristic of each solvent vapor. It was discovered that temperature programming between solvent vapor exposures greatly improved the reproducibility of the luminescence spectra obtained. A statistical analysis of three-dimensional resolution factors between pairs of solvent clusters in principal component space supported this assertion. The success of the temperature programming protocol was limited by the thermal stability and the sensitivity to low background water vapor levels of some platinum(II) double salt materials. The ability of the cross-reactive sensor array to differentiate between two different solvent vapors over a large concentration range was also investigated. Acetone and methanol were found to occupy two distinct regions of the three-dimensional principal component space. Detection limits for acetone and methanol were estimated from the principal component analysis as 75 and 6 g/m3, respectively.Keywords
This publication has 27 references indexed in Scilit:
- Steplike Response Behavior of a New Vapochromic Platinum Complex Observed with Simultaneous Acoustic Wave Sensor and Optical Reflectance MeasurementsChemistry of Materials, 2002
- Conductivity of Triiodide Salts in Vapor-Swollen Commodity PolymersChemistry of Materials, 2000
- Solvent- and Vapor-Induced Isomerization between the Luminescent Solids [CuI(4-pic)]4 and [CuI(4-pic)]∞ (pic = methylpyridine). The Structural Basis for the Observed Luminescence VapochromismChemistry of Materials, 2000
- Linker-Enhanced Binding of Metalloporphyrins to Cadmium Selenide and Implications for Oxygen DetectionLangmuir, 2000
- Detection of Fluorophosphonate Chemical Warfare Agents by Catalytic Hydrolysis with a Porous Silicon InterferometerJournal of the American Chemical Society, 2000
- Infrared Spectroscopy Studies of Platinum Salts Containing Tetracyanoplatinate(II). Evidence for Strong Hydrogen-Bonding Interactions in “Vapochromic” Environmental Sensor MaterialsChemistry of Materials, 1998
- Linear Chain Au(I) Dimer Compounds as Environmental Sensors: A Luminescent Switch for the Detection of Volatile Organic CompoundsJournal of the American Chemical Society, 1998
- Array-Based Vapor Sensing Using Chemically Sensitive, Carbon Black−Polymer ResistorsChemistry of Materials, 1996
- Inclusion of Organic Vapors by Crystalline, Solvatochromic [Pt(aryl isonitrile)4][Pd(CN)4] Compounds. "Vapochromic" Environmental SensorsChemistry of Materials, 1995
- Analysis of discrimination mechanisms in the mammalian olfactory system using a model noseNature, 1982