Multicenter Study of the LCx® HIV RNA Quantitative Assay – a New Competitive Reverse Transcriptase-PCR which Targets pol Genomic Region of HIV-1 for the Measurement of Type B, Non-Type B and Group O HIV-1 RNA
- 24 January 2002
- journal article
- research article
- Published by Walter de Gruyter GmbH in cclm
- Vol. 40 (7) , 698-704
- https://doi.org/10.1515/cclm.2002.120
Abstract
Performance characteristics of the Abbott LCx® HIV RNA Quantitative Assay (LCx HIV) were established in a multicenter study comparing it with the manual (Amplicor v1.5) and automated (Cobas) ultra-sensitive Roche Amplicor™ HIV-1 Monitor v1.5, the Bayer Quantiplex™ HIV RNA 3.0 (bDNA v3.0), and the Organon NucliSens® HIV QT 2.0 (NucliSens). Within-run precision of LCx HIV assessed in clinical specimens was SD log10 0.210 at ~50 copies/ml, and log10 0.133 at ~400 copies/ml. Total precision in a reconstituted type B HIV-1 RNA panel was SD log10 0.380 at 100 copies/ml, and SD log10 0.180 at 1000 copies/ml. Type B HIV-1 RNA sensitivity (1 ml input) assessed at a 50%, 75% and 95% detection rate ranged from 29 to 41, 54 to 75 and 94 to 176 copies/ml, respectively. Overall specificity in HIV sero-negative individuals was 99.78%. Linear regression indicated close assay correlations and agreements for measurement of type B HIV-1 RNA. Pearson's correlations and (Log10LCx=aLog10x + b) linear regressions were 0.91 (y=0.892 Log10Amplicor + 0.595), 0.93 (y=0.827 Log10Cobas + 0.969), 0.93 (y=0.951 Log10bDNA + 0.550), and 0.79 (y=0.834 Log10nuclisens + 0.911). LCx HIV was least affected by the genetic variability of HIV-1. LCx HIV detected 99% of non-type B HIV-1 group M samples (subtypes A-G), Amplicor v1.5 detected 96%, and bDNA v3.0 detected 99%. The assays detected 10/11, 1/11 and 8/11, respectively of the HIV-1 group O samples. LCx HIV vs. Amplicor/bDNA Spearman's rank correlations for quantification of non-type B HIV-1 RNA were 0.76/0.84 (A), 0.93/0.93 (C), 0.73/0.99 (D), 0.86/0.98 (E), and 0.40/0.83 (group O). LCx HIV assays consistently detect and quantify type B, non-type B and group O HIV-1 RNA.Keywords
This publication has 23 references indexed in Scilit:
- Mother-to-Child Transmission in the United States of Subtypes D and A/G Human Immunodeficiency Virus Type 1AIDS Research and Human Retroviruses, 2002
- Evaluation of the Abbott LCx Quantitative Assay for Measurement of Human Immunodeficiency Virus RNA in PlasmaJournal of Clinical Microbiology, 2002
- Use of Indicators to Evaluate the Quality of Community-Acquired Pneumonia ManagementClinical Infectious Diseases, 2002
- Travel and the Introduction of Human Immunodeficiency Virus Type 1 Non‐B Subtype Genetic Forms into Western CountriesClinical Infectious Diseases, 2001
- Erroneously Low or Undetectable Plasma Human Immunodeficiency Virus Type 1 (HIV-1) Ribonucleic Acid Load, Determined by Polymerase Chain Reaction, in West African and American Patients with Non-B Subtype HIV-1 InfectionClinical Infectious Diseases, 2001
- Clinical Implications of Identifying Non-B Subtypes of Human Immunodeficiency Virus Type 1 InfectionClinical Infectious Diseases, 2000
- Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypesJournal of Clinical Virology, 1999
- Assay of Plasma Samples Representing Different HIV-1 Genetic Subtypes: An Evaluation of New Versions of the Amplicor HIV-1 Monitor AssayAIDS Research and Human Retroviruses, 1999
- Comparison of Three Different Commercial Methods for Measuring Plasma Viraemia in Patients Infected with Non-B HIV-1 SubtypesEuropean Journal of Clinical Microbiology & Infectious Diseases, 1999
- HIV viral load markers in clinical practiceNature Medicine, 1996