Membrane filter method for enumerating Escherichia coli
- 1 May 1981
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 41 (5) , 1152-1158
- https://doi.org/10.1128/aem.41.5.1152-1158.1981
Abstract
A membrane filter procedure for enumerating Escherichia coli was developed and evaluated. The method quantifies E. coli within 24 h without requiring subculture and identification of isolates. It incorporates a primary selective-differential medium for gram-negative, lactose-fermenting bacteria; resuscitation of weakened organisms by incubation for 2 h at 35 degrees C before incubation at 44.5 degrees C for 18 to 22 h; and an in situ urease test to differentiate E. coli from other thermotolerant, lactose-positive organisms. The recovery of E. coli from marine, estuarine, and freshwater samples exceeded 90%. Of the presumptively positive colonies, 91% were verified as E. coli. Less than 1% of all of the verified E. coli colonies failed to react typically.This publication has 8 references indexed in Scilit:
- Two-temperature membrane filter method for enumerating fecal coliform bacteria from chlorinated effluentsApplied and Environmental Microbiology, 1977
- Improved membrane filter method for fecal coliform analysis.1975
- A single medium for the rapid detection ofEscherichia coliat 44°CEpidemiology and Infection, 1973
- Four-hour urease test for distinguishing between Klebsiella and Enterobacter.1969
- Statistical concepts in microbiology.1955
- Improved methods for determining the most probable number ofBacterium coliand ofStreptococcus faecalisEpidemiology and Infection, 1953