Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin
Open Access
- 6 January 1998
- journal article
- research article
- Published by Proceedings of the National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 95 (1) , 294-299
- https://doi.org/10.1073/pnas.95.1.294
Abstract
The kinetics of the fall in subcutaneous fluid glucose concentration in anesthetized rats (n = 7) after intravenous injection of insulin (0.5 units/kg) was studied by using 5 × 10−4 cm2 active area, P < 0.001) from that in blood (8.9 ± 2.1 min vs. 3.3 ± 0.5 min). Similarly, the rate of drop in glucose concentration between 6 and 20 min after the insulin injection was different for subcutaneous tissue (3.9 ± 1.3 mg⋅dl−1⋅ min−1) and blood (6.8 ± 2.0 mg⋅dl−1⋅min−1) (P = 0.003). The hypoglycemic nadir in subcutaneous fluid occurred 24.5 ± 6.8 min after that in the blood (P < 0.001). A “forward” mass-transfer model, predicting the subcutaneous glucose concentration from the blood glucose concentrations and an “inverse” model, predicting the blood glucose concentration from the subcutaneous glucose concentration were derived. By using an algorithm based on the latter, the average discrepancy between the measured blood glucose concentration and that estimated from the subcutaneous measurement through the entire 4-hr experiment was reduced from 22.9% to 11.1% (P = 0.025). The maximum discrepancy during the 40-min period after the injection of insulin was reduced from 84.1% to 29.3% (P = 0.006).This publication has 21 references indexed in Scilit:
- Accuracy of home blood glucose meters during hypoglycemiaDiabetes Care, 1996
- Battery-Powered Miniature Bipotentiostats for Amperometric BiosensorsInstrumentation Science & Technology, 1996
- Use of a Subcutaneous Glucose Sensor To Detect Decreases in Glucose Concentration Prior to Observation in BloodAnalytical Chemistry, 1996
- Adverse Events and Their Association With Treatment Regimens in the Diabetes Control and Complications TrialDiabetes Care, 1995
- Kinetic analysis of glucose transporter trafficking in fibroblasts and adipocytesBiochemistry, 1995
- Design and Optimization of a Selective Subcutaneously Implantable Glucose Electrode Based on "Wired" Glucose OxidaseAnalytical Chemistry, 1995
- Design, Characterization, and One-Point in vivo Calibration of a Subcutaneously Implanted Glucose ElectrodeAnalytical Chemistry, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- On Line Continuous Monitoring of Subcutaneous Tissue Glucose is Feasible by Combining Portable Glucosensor with MicrodialysisHormone and Metabolic Research, 1993
- In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transferDiabetologia, 1989