Analysis of ciliary beat pattern and beat frequency using digital high speed imaging: comparison with the photomultiplier and photodiode methods
Open Access
- 1 April 2000
- Vol. 55 (4) , 314-317
- https://doi.org/10.1136/thorax.55.4.314
Abstract
BACKGROUND The aim of this study was to determine the relationship of the power and recovery stroke of respiratory cilia using digital high speed video imaging. Beat frequency measurements made using digital high speed video were also compared with those obtained using the photomultiplier and modified photodiode techniques. METHOD Ciliated epithelium was obtained by brushing the inferior nasal turbinate of 20 healthy subjects. Ciliated edges were observed by microscopy and the deviation of cilia during their recovery stroke relative to the path travelled during their power stroke was measured. Beat frequency measurements made by digital high speed video analysis were compared with those obtained using the photomultiplier and modified photodiode. RESULTS Cilia were found to beat with a forward power stroke and a backward recovery stroke within the same plane. The mean angular deviation of the cilia during the recovery stroke from the plane of the forward power stroke was only 3.6°(95% CI 3.1 to 4.1). There was a significant difference in beat frequency measurement between the digital high speed video (13.2 Hz (95% CI 11.8 to 14.6)) and both photomultiplier (12.0 Hz (95% CI 10.8 to 13.1), p = 0.01) and photodiode (11.2 Hz (95% CI 9.9 to 12.5), pCONCLUSION Respiratory cilia beat forwards and backwards within the same plane without a classical sideways recovery sweep. Digital high speed video imaging allows both ciliary beat frequency and beat pattern to be evaluated.Keywords
This publication has 17 references indexed in Scilit:
- Primary ciliary dyskinesia: diagnosis and standards of careEuropean Respiratory Journal, 1998
- The assessment of nasal mucociliary clearance and the effect of drugsRespiratory Medicine, 1994
- Ciliary Function, Cell Viability, and in Vitro Effect of Ribavirin on Nasal Epithelial Cells in Acute RhinorrheaChest, 1992
- Ciliary beat frequency in newborn infants.Archives of Disease in Childhood, 1991
- Ciliary abnormalities in respiratory disease.Archives of Disease in Childhood, 1988
- Primary ciliary dyskinesia: Evaluation and managementPediatric Pulmonology, 1988
- A versatile and quantitative computer‐assisted photoelectronic technique used for the analysis of ciliary beat cyclesCell Motility, 1985
- NON-INVASIVE SAMPLING OF NASAL CILIA FOR MEASUREMENT OF BEAT FREQUENCY AND STUDY OF ULTRASTRUCTUREThe Lancet, 1980
- High Speed Cinemicrographic Studies on Rabbit Tracheal (Ciliated) Epithelia: Determination of the Beat Pattern of Tracheal CiliaPediatric Research, 1976
- Frequency of Ciliary Beat measured with a Photo-sensitive CellNature, 1962