Petrosal Bone: Coronal Reconstructions from Axial Spiral CT Data Obtained with 0.5-mm Collimation Can Replace Direct Coronal Sequential CT Scans
- 1 November 1999
- journal article
- clinical trial
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 213 (2) , 375-382
- https://doi.org/10.1148/radiology.213.2.r99nv11375
Abstract
PURPOSE: To investigate whether coronal multiplanar reconstruction (MPR) images of the petrosal bone from axial spiral computed tomographic (CT) data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans obtained with 0.5- or 1.0-mm collimation. MATERIALS AND METHODS: The differences in diagnostic quality between thin-section coronal sequential CT scans of 24 petrosal bones in 12 patients and matched MPR images were assessed by five observers. The matched MPR images were calculated with both trilinear and tricubic interpolation. Image resolution was determined by measuring the three-dimensional point spread function. RESULTS: All observers preferred tricubically interpolated MPR images over trilinearly interpolated images. Subjective differences in image quality between direct coronal scans and matched tricubically interpolated MPR images were small. Only the direct coronal scans with the highest image quality (0.5-mm collimation, 465 mAs) were judged to be slightly better than the matched MPR images. With regard to direct coronal scans obtained at 245 mAs and/or 1.0-mm collimation, either there was no preference or the MPR images were preferred. CONCLUSION: Coronal MPR images from axial spiral CT obtained with 0.5-mm collimation can replace direct coronal sequential CT scanKeywords
This publication has 14 references indexed in Scilit:
- Analysis of Interpolation Effects in the Reslicing of Functional MR ImagesJournal of Computer Assisted Tomography, 1997
- Normal and opacified middle ears: CT appearance of the stapes and incudostapedial joint.Radiology, 1997
- Modulation transfer functions of single-slice and dual-slice computed tomography scannersMedical Physics, 1996
- Dual‐slice spiral versus single‐slice spiral scanning: Comparison of the physical performance of two computed tomography scannersMedical Physics, 1996
- Spiral CT of the temporal bone: value of image reconstruction at submillimetric table incrementsNeuroradiology, 1995
- Automatic three‐dimensional correlation of CT‐CT, CT‐MRI, and CT‐SPECT using chamfer matchingMedical Physics, 1994
- Hierarchical chamfer matching: a parametric edge matching algorithmPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1988
- The technique of direct multiplanar high resolution CT of the temporal boneNeurosurgical Review, 1985
- Computed tomography of the middle ear in the evaluation of cholesteatomas and other soft-tissue masses: comparison with pluridirectional tomography.Radiology, 1983
- A Simplex Method for Function MinimizationThe Computer Journal, 1965