GATE: a simulation toolkit for PET and SPECT
Top Cited Papers
- 10 September 2004
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (19) , 4543-4561
- https://doi.org/10.1088/0031-9155/49/19/007
Abstract
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http://www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- Intercomparison on the usage of computational codes in radiation dosimetryRadiation Protection Dosimetry, 2004
- Simulation of time curves in small animal PET using GATENuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Monte Carlo simulation in PET and SPECT instrumentation using GATENuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- GATE: a Geant4-based simulation platform for PET and SPECT integrating movement and time managementIEEE Transactions on Nuclear Science, 2003
- From PET detectors to PET scannersEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- GATE (geant4 application for tomographic emission): a PET/SPECT general-purpose simulation platformNuclear Physics B - Proceedings Supplements, 2003
- γ-ray spectra from positron annihilation on atoms and moleculesPhysical Review A, 1997
- BEAM: A Monte Carlo code to simulate radiotherapy treatment unitsMedical Physics, 1995
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43Medical Physics, 1995
- A review of pseudorandom number generatorsComputer Physics Communications, 1990