Catheter Ablation of Common‐Type Atrial Flutter Guided by Three‐Dimensional Right Atrial Geometry Reconstruction and Catheter Tracking Using Cutaneous Patches:
- 1 October 2004
- journal article
- clinical trial
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 15 (10) , 1157-1161
- https://doi.org/10.1046/j.1540-8167.2004.04064.x
Abstract
EnSite NavX (NavX) is a novel mapping and navigation system that allows visualization of conventional catheters for diagnostic and ablative purposes and uses them to create a three-dimensional (3D) geometry of the heart. NavX is particularly suitable for ablation procedures utilizing an anatomic approach, as in the setting of common-type atrial flutter (AFL). The aim of this study was to compare NavX-guided and conventional ablation procedures for AFL. Forty consecutive patients (32 male, 59 +/- 12 years) with documented AFL were randomized to undergo fluoroscopy-guided (group I, 20 patients) or NavX-guided (group II, 20 patients) ablation, including 3D isthmus reconstruction. The same catheter setup was used in both groups. The endpoint of bidirectional isthmus block was obtained in all patients. Compared to conventional approaches, NavX-guided procedures significantly reduced fluoroscopy time (5.1 +/- 1.4 min vs 20 +/- 11 min, P < 0.01) and total x-ray exposure (5.1 +/- 3.1 Gycm2 vs 24.9 +/- 1.6 Gycm2, P < 0.01). Isthmus geometry reconstruction could be performed in all patients of group II. In 4 patients (20%) of group II, anatomic isthmus variations were detected by NavX. No significant differences in radiofrequency current applications and procedural times were found between the two groups. NavX technology allows geometry reconstruction of the cavotricuspid isthmus. NavX-guided ablation of AFL reduces total x-ray exposure compared to the fluoroscopy-guided approach but does not prolong procedure time.Keywords
This publication has 7 references indexed in Scilit:
- Phased‐Array Intracardiac Echocardiography for Defining Cavotricuspid Isthmus Anatomy During Radiofrequency Ablation of Typical Atrial FlutterJournal of Cardiovascular Electrophysiology, 2003
- LocaLisa Catheter Navigation Reduces Fluoroscopy Time and Dosage in Ablation of Atrial Flutter:Journal of Cardiovascular Electrophysiology, 2003
- Large Tip Electrodes for Successful Elimination of Atrial Flutter Resistant to Conventional Catheter AblationJournal of Interventional Cardiac Electrophysiology, 2003
- Catheter Ablation of Atrial Flutter Guided by Electroanatomic Mapping (CARTO): A Randomized Comparison to the Conventional ApproachJournal of Cardiovascular Electrophysiology, 2000
- Electromagnetic Versus Fluoroscopic Mapping of the Inferior Isthmus for Ablation of Typical Atrial FlutterCirculation, 2000
- Right Atrial Angiographic Evaluation of the Posterior IsthmusCirculation, 2000
- LocaLisaCirculation, 1999