Quantitative TLC of Toxic Elements on Inorganic Ion-Exchangers. IV. Cadmium and Lead
- 1 July 1992
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 15 (10) , 1681-1687
- https://doi.org/10.1080/10826079208018319
Abstract
Thin layers of Stannic Silicate, an inorganic ion-exchanger, have been used to develop fast and selective methods for the separation of micro-quantities of Cadmium and Lead from other elements. Direct determinations of Cadmium and Lead have been made under chosen sutiable conditions by the help of Camag TLC Scanner.Keywords
This publication has 3 references indexed in Scilit:
- Thin-layer chromatographic separation of platinum metals on a semi-crystalline inorganic ion-exchangerMicrochimica Acta, 1978
- Thin layer chromatography of 57 metal ions on an inorganic ion-exchanger in mixed solvent systemsChromatographia, 1975
- Thin layer chromatography of metal ions on a new synthetic inorganic ion-exchangerCellular and Molecular Life Sciences, 1972