Enhanced wear performance of highly crosslinked UHMWPE for artificial joints
- 23 March 2000
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 50 (3) , 381-387
- https://doi.org/10.1002/(sici)1097-4636(20000605)50:3<381::aid-jbm12>3.0.co;2-p
Abstract
It is well known that osteolysis induced by polyethylene wear debris is the main cause of long-term failure of hip and knee prostheses. We developed a treatment of medical-grade ultra-high molecular-weight polyethylene (UHMWPE) in order to improve its tribologic properties and reduce its wear. Medical-grade UHMWPE was irradiated with a 200 kGy dose of radiation, thermally stabilized at a temperature close to the melting point, and then sterilized with ethylene oxide. The irradiation treatment was performed to crosslink the UHMWPE. The thermal stabilization treatment, contributing to the reaction between the free radicals generated by the irradiation process, was chosen to enhance crosslinking and to prevent oxidation and the shortening of chains. The non-invasive sterilization process with ethylene oxide was chosen to prevent the re-formation of free radicals. The wear performance of this material was compared to UHMWPE, untreated or treated with different sterilization techniques, using γ and β irradiation. Insoluble crosslinked constituents were measured with an extraction method. Wear was evaluated using a flat-on-ring wear test machine. While small differences were found among the different sterilization processes, 200 kGy-irradiated UHMWPE followed by thermal treatment and sterilization with ethylene oxide had the least wear and the greatest amount of crosslinking. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 50, 381–387, 2000.Keywords
This publication has 16 references indexed in Scilit:
- Impact of gamma sterilization on clinical performance of polyethylene in the kneeThe Journal of Arthroplasty, 1996
- Periprosthetic Osteolysis in Total Hip ArthroplastyJournal of Bone and Joint Surgery, 1995
- Histologic investigations on 33 retrieved Nobelpharma implantsClinical Materials, 1993
- Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplastyThe Journal of Arthroplasty, 1992
- Size of metallic and polyethylene debris particles in failed cemented total hip replacementsThe Journal of Bone and Joint Surgery. British volume, 1992
- Debris-Mediated Osteolysis—A Cascade Phenomenon Involving Motion, Wear, Particulates, Macrophage Induction, and Bone LysisPublished by ASTM International ,1992
- The histological effects of the implantation of different sizes of polyethylene particles in the rabbit tibiaJournal of Biomedical Materials Research, 1990
- Radiation sterilization and the wear rate of polyethyleneJournal of Orthopaedic Research, 1984
- Low Friction Arthroplasty of the HipPublished by Springer Nature ,1979
- Rate of Wear in Total Hip ReplacementClinical Orthopaedics and Related Research, 1975