Effects of humic materials on virus recovery from water
- 1 May 1985
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 49 (5) , 1260-1264
- https://doi.org/10.1128/aem.49.5.1260-1264.1985
Abstract
Humic and fulvic acids were tested for their ability to interfere with virus recovery by microporous filters. Two electropositively charged types of filter (Seitz S and Zeta Plus 60S) were used to concentrate poliovirus in the presence of humic materials. Humic acid inhibited virus adsorption, but even at the highest humic acid concentrations tested (200 mg/liter), 30 to 40% of the virus was recovered by the filters. Fulvic acid, tested with Zeta Plus filters, did not affect virus recovery. For comparison, two electronegatively charged filter types were tested (Cox and Balston). These two types of filter were more sensitive to interference at lower concentrations of humic acid than the more positively charged filters. With Balston filters, at humic acid concentrations above 10 mg/liter, most of the virus was recovered in the filtrate. Fulvic acid, tested with Balston filters, did not interfere with virus recovery. With the electropositively charged filters, the humic materials adsorbed efficiently, even at high input concentrations. Interference with virus adsorption occurred at humic acid concentrations which were below the level of saturation of the filters. In addition, in high-volume experiments, humic acid led to premature blockage of the filters. The efficiency of virus recovery by a second concentration step, organic flocculation of the filter eluate, was tested. For all the filter types tested, this procedure was not affected by the presence of humic or fulvic acid in the input water.This publication has 13 references indexed in Scilit:
- A comparison of current methods of poliovirus concentration from tap waterWater Research, 1985
- Concentration of Simian Rotavirus SA-11 from Tap Water by Membrane Filtratiòn and Organic FlocculationApplied and Environmental Microbiology, 1983
- Positively charged filters for virus recovery from wastewater treatment plant effluentsApplied and Environmental Microbiology, 1981
- Poliovirus concentration from tap water with electropositive adsorbent filtersApplied and Environmental Microbiology, 1980
- Concentration of Viruses from Water by Membrance ChromatographyAnnual Review of Microbiology, 1979
- Concentration of poliovirus from tap water using positively charged microporous filtersApplied and Environmental Microbiology, 1979
- Organic Flocculation: an Efficient Second-Step Concentration Method for the Detection of Viruses in Tap WaterApplied and Environmental Microbiology, 1976
- Characteristics of humic acid and organic compounds concentrated from tapwater using the aquella virus concentratorWater Research, 1975
- Environmental factors influencing isolation of enteroviruses from polluted surface waters.1974
- Characterization of type 1 poliovirus by electrophoretic analysisVirology, 1971